T
High acceleration and deceleration DD motor SGM7F-36B7A-YS11, equipped with a 24 bit encoder; Adopting a small diameter rotor with a compact structure, it can directly drive a high inertia turret system.
Capable of achieving high-speed and high-frequency positioning. Rated speed 330min-1, maximum speed 400 min-1. Rated torque 36N · m, maximum torque 110N · m.
Low inertia and low heat generation, suitable for application scenarios that require compact size and high efficiency.
Electromagnetic noise, which only occurs under the energized state of the motor, can be determined as electromagnetic noise. As long as it is powered off and on, it can be determined as electromagnetic noise. When there is obvious noise during the operation of the motor, if the noise disappears immediately after power off, it can be determined as electromagnetic noise; If the conditions for voltage regulation are met, voltage regulation can be carried out within the range below the rated voltage of the motor. The higher the voltage, the greater or more obvious the noise, which is also judged as electromagnetic noise from another level.
Ventilation noise refers to the method of blocking the air circuit used in the motor thermal test process, which is particularly effective in determining whether it is ventilation noise. By blocking the air inlet of the motor, if the noise of the motor is significantly reduced, it is basically determined that there is a strong tendency for ventilation noise.
For the mechanical noise of a motor, it is mainly caused by friction or resonance of its associated components. When the rotor part of the motor is stationary, regardless of whether it is powered on or not, mechanical noise will not be generated. The magnitude and sound effect of mechanical noise are directly related to the speed of the motor. When the speed is low, mechanical noise appears as periodic intermittent noise, while when the motor speed is high, The sound is converted into a continuous sound effect that is difficult to recognize by hearing, and the mechanical noise does not disappear when the motor is powered off, but the sound will change as the speed decreases.
For variable frequency motors, electromagnetic noise, mechanical noise, and ventilation noise will fluctuate with changes in power frequency, such as severe electromagnetic noise, mechanical resonance noise, etc. within a specific frequency band.
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
Signal input
Signal type: Transistor (PNP&NPN compatible)
NPN signal level (input): NPN: 0-5VDC
PNP signal level (input): PNP: 15-30VDC
Single channel consumption current: 5mA
Port protection (input): overvoltage impact protection
Input characteristics: NPN/PNP (compatible)
Electrical isolation: AC 500V
signal output
Signal type: relay
Rated level: relay 250VAC/30VDC
Single channel rated current: Relay: 5A
Port protection (output): overvoltage and overcurrent protection
Electrical isolation: AC 500V
General parameters
Protection level: IP20
Working temperature: 0-55 ℃
Storage temperature: -25~85 ℃