Product Details

LGK16.333A17 AC110V Siemens combustion controller

Brand Name Siemens
Place of Origin Germany
Model Number LGK16.333A17 AC110V

Product Features

LGK16.333A17 - gas burner control, t1=31.5s, TSA=3s, AC110V


LFL1... burner control device designed specifically for forced air burner control and monitoring can be used for direct ignition or medium to high power burners with ignition burners. Fuel and gas are universal and can be applied to fixed preheating air burners WLE according to DIN 4794 standard


The difference between the 01 series and the 02 series lies in: ① the safety time of ignition burners with ignition gas valves is different; ② the controller for high-power atmospheric combustion is LFL1.638. If the burner needs continuous operation control, ③ for burners using ignition gas valves, the safety time is different.  


After the allowed post ignition time of LFL1, the detection electrode and flame simulation test are immediately restored. The fuel valve that is not closed or not closed immediately locks the controller unit of the burner after the allowed afterburning time. The detection electrode and flame simulation inspection only ends when the pre purge time at the next burner start is completed- During each start-up of the burner, the correct operation of the flame monitoring circuit is automatically verified- The controller contacts used to release fuel are inspected during each subsequent purge time to ensure that the contacts do not close- A built-in fuse unit protects the contacts of the controller from overload.


     


T1 Pre purge time TAS Safe ignition time TAS Safe ignition time t3 Pre ignition time t3 Pre ignition time, Terminal 17 releases voltage t4 from t2 to terminal 19 releases voltage t5 from t4 to terminal 20 releases voltage t6 after purging time t7 starts command to terminal 7 releases voltage t9 safety time t10 starts to air pressure control start t11 full open time t12 full close time t13 allows for post purge time after shutdown t16 starts command to full open command interval t20 stops without post purging, Until next start interval


DANFOSS nozzle, HAGO nozzle, STEINEN nozzle. Atomized shapes are solid (S), semi solid (B), and hollow (H). Spray angle 45 degrees, 60 degrees, 80 degrees, etc. Weisaupt models W50-110, W50-125, W50-140, W50-160, W50-180, W50-220, W50-225, W50-250, W50-275, W50-300, W50-330, W50-360, W50-390, W50-420, W50-490. Programmable controller


SIEMENS series programmable controllers


SIEMENS program controller LOA24.171B27, SIEMENS program controller LOA44.252A27


SIEMENS program controller LMO44.255C2, SIEMENS program controller LAL1.25


SIEMENS program controller LAL2.25, LAL1.25BT, LAL2.25BT, LAL1.25EM, LAL2.25EM, LAL1.25RL, LAL2.25RL), SIEMENS program controller LFL1.322, SIEMENS program controller LFL1.335, SIEMENS program controller LFL1.333, SIEMENS program controller LFL1.635, LFL1.322BT, LFL1.335BT, LFL1.333BT, LFL1.635BT,


LFL1.322RL、LFL1.335RL、LFL1.333RL、LFL1.635RL,LFL1.322EM、LFL1.335EM、LFL1.333EM、LFL1.635EM


SIEMENS combustion program controller


LFL combustion process controller LFL1.333, LFL1.322, LFL1.335, LFL1.635, LFL1.622


LAL fuel combustion controller LAL1.25, LAL2.25, LAL3.25, LAL2.14, LFL1.333BC


LGK dual purpose combustion controllers LGK16.333A27, LGK16.322A27, LGK16.335A27, LGK16.335A27, LGK16.622A27


LOK16 fuel combustion controller LOK16.250A27,


LMV5 series air fuel ratio combustion management systems LMV51.100C2, LMV52.200B2,


LEC1 large combustion controller LEC1/8892, LEC1/8851, LEC1/8853, LFE1/8851,


LFE1 intermittent operation gas combustion controller with any capacity LFE1/8851, LFE1/8853


LGB2 mechanical combustion controller LGB21.330A27, LGB22.330A27, LMG22.330B27





Siemens LDU11 gas leak detector LDU11.523A27, LDU11.323A27,


LMV27 Electronic Air Fuel Ratio Controller LMV27.100A2


LME7 integrated functional controllers LME71.0000A2, LME73.0000A2


AZL display operation units AZL21.00A9, AZL23.00A9, AZL52.00B1, AZL52.401


Siemens proportional regulators RWF50.20A9, RWF50.30A9, RWF55.50A9


Siemens power adapter AGG5.220, AGG3.131,


Siemens speed sensor AGG5.315


Siemens analog input modules AGG56.41A27, AGG56.91A27


KF8804 Siemens LFL1 testing unit, PLL52.110A200 flue gas oxygen measurement module


AGO20.002A flue gas collector, AG flame detector auxiliary component,





Combustion controller • For medium and large capacity burners with forced ventilation for fuel, gas, or dual fuel • For intermittent operation burners with multiple sections or continuous proportions • With damper detection • Flame monitoring - UV flame detector QRA The ion probe LFL1... series controller is particularly suitable for OEM manufacturers who integrate combustion control into their products Purpose - Monitoring forced draft burners with expandable flames or pilot flame (ignition) interruptible structures - Medium to high capacity - Intermittent operation (with at least one controlled shutdown every 24 hours) - Multi stage or continuous proportional burners - Dual fuel burners - Fixed air preheaters 01 and 02 series. For pilot flame (ignition) burners equipped with pilot flame gas valves, the main difference lies in the length of safety time. LFL1.638 is suitable for large capacity atmospheric burners




This burner control is used to continuously operate multi-stage or regulate medium to high capacity burners, and check the air damper control through air pressure monitoring. The burner control device has passed the EN298 and CE certification, and complies with the gas appliance and electromagnetic compatibility directives. The functions include fault lock indicator light, fault signal light, and reset button.


The burner control unit has a self checking flame monitoring circuit, which not only starts the required safety measures when the flame signal is too early or missing, but also when any fault occurs in the flame detector, cable or flame signal amplifier (which may simulate the flame signal during burner operation). This control device is reliable and suitable for a wide range of applications, including fuel and gas combustion plants that must use self checking flame monitoring systems, such as continuous use burners, intermittent operation burners, and burners in factories that require self checking for burner monitoring due to safety requirements. Suitable for gas, oil, and dual fuel burners.




Burner control is suitable for: medium to high capacity gas, oil, or dual fuel forced ventilation burners, intermittently operated multi-stage or adjustable burners, with inspected air damper control, flame supervision, and equipped with ultraviolet detector QRA And ionization probe, burner control for oil or gas burners in accordance with EN 298:2012, suitable for air heaters (WLE)






Shanghai Pingkai Automation Equipment Co., Ltd. is specialized in the sales of industrial control automation products, system integration, electrical equipment sales, and electromechanical equipment sales.




Siemens Programmable Controller S7-200CN ET-200 S7-200 S7-300 S7-400 S7-1200 S7-1500 smartS7-200




Siemens touch screen OP77-TP series MP277 MP377 TD200-TD400C




Siemens Communication Accessories DP Cable Ethernet Cable DP Connector Communication Card




Siemens motor V60-V80 servo motor 1FT servo motor Bede motor 1FK motor




Siemens frequency converter V10 series MM440 series G110 series G120 series




Siemens CNC system 810D system 840D system 808D 8404DSL




Siemens frequency converter series: MM420, MM430, MM440, G110, G120. MIDASTER series




Siemens fully digital DC speed control device 6RA23, 6RA24, 6RA28, 6RA70, 6SE70 series




Siemens actuators, burners, controllers, electric eyes, flame detectors, modules, operation panels, etc




Siemens SQN, SQM, AGG, LFL, LME, LMV, QRA, SKP, VGD, VGF, VRD and other series products


You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now