Product Details

Acrel Din rail 35mm leakage fault current operated relay protective device for sale

Product Features

Products Description
ASJ10-LD1A Residual Current Relay
ASJ Series Residual Current Relay 
ACREL ASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below. ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.


* The measurement of A-type after-current
* The streamer display of current percentage; * The setting of rated residual action current * The setting of non-driving time of limitation * Two- pair relay output * Possessing the function of on-the-spot and long- distance testing and resetting* Frequency: 50Hz±5Hz * Auxiliary power supply: AC110V, AC220V, DC85 ~270V (permissible error±10%) * Consumption: ≤5W

Frequency 50Hz±5Hz
Auxiliary power supply AC110V, AC220V, DC85 ~270V (permissible error ±10%) Consumption ≤5W

Installation Din rail 35mm Dimension(L*W*H) 85*54*64mm
Types of Product
Type
Function
Installation
ASJ10-LD1C
AC-type residual current measurement;
Alarm prompt of current crossing line;
Rated residual operating current can be measured;
Limit non-driving time can be set;
Two sets of relay output;
With local and remote “test” and “reset” functions.














Guide
(DIN
35mm)
ASJ10-LD1A
A-type residual current measurement;
Current percentage light column display;
Rated residual operating current can be measured;
Limit non-driving time can be set;
Two sets of relay output (settable)note 1;
With local and remote “test” and “reset” functions.
ASJ10L-LD1A
note2
A-type residual current measurement;
Rated residual operating current can be measured;
Limit non-driving time can be set;
Two sets of relay output (settable);
Transformer breakage alarm can be set;
Pre-alarm value can be set;
Return value can be set.
With on-site display, remote "test", "reset"
LCD display, 25 event records.
ASJ20-LD1C
AC-type residual current measurement;
Alarm prompt of current crossing line;
Rated residual operating current can be measured;
Limit non-driving time can be set;
Two sets of relay output;
With local and remote “test” and “reset” functions.







Panel
(48*48)
ASJ20-LD1A
A-type residual current measurement;
Current percentage light column display;
Rated residual operating current can be measured;
Limit non-driving time can be set;
Two sets of relay output (settable)note 1;
With local and remote “test” and “reset” functions.
Note 1: The function of setting for relay means that you can set the initialization and the output state of relay by yourself through the code dialing on the panel; the specific setting guide can be found from the chapter 5.2.
Note 2: Optional function, RS485 interface, Modbus-RTU Communication, type is ASJ10L-LD1A/C.
Technical Parameter
Technical Parameter
Indicator
AC type
A type
Power supply
Voltage range
AC110V、AC220V
(±10%)
AC/DC85~265V
Power dissipation
≤5W
Input
Rated residual operating current I△n
0.03、0.1、0.3、0.5(A)
0.03、0.05、0.1、0.3、0.5、1、3、5、10、30(A)note 3
Limit non-driving time △t
0.1、0.5(s)
0、0.06、0.1、0.2、0.3、0.5、0.8、1、4、10(s)note 4
Rated residual non-operating current I△no
50%I△n
50%I△n
Performance characteristics
Sinusoidal AC
Sinusoidal AC and pulsating DC
Frequency
50Hz±5Hz
50Hz±5Hz
Operating range
-20% ~ -10%I△n
-20% ~ -10%I△n
Output
Output mode
One is normally open and another is for transformation
One is normally closed or open, and another is for transformation
Contact capacity
5A 250VAC
5A 30VDC
AL1:8A 250VAC; 5A 30VDC
AL2:6A 250VAC; 5A 30VDC
Reset mode
Local reset or remote reset
Local reset, remote reset or automatic reset
Installation and use environment
Temperature
Run temperature:-20℃ ~ +55℃,Storage temperature:-30℃ ~ +70℃
Humidity
≤95%RH,no condensation, and no corrosive gas places
Elevation
≤2000m
Class of pollution
Grade three
Installation category
Type Ⅲ
Note 3: ASJ10L-LD1A rated residual operating current IΔn is 10mA~30A continuously adjustable; Note 4: ASJ10L-LD1A limit non-driving time Δt is 0~10S continuously adjustable.