Product Details

GRBTU 3BSE013175R1

Brand Name ABB
Place of Origin China
Model Number GRBTU 3BSE013175R1

Product Features

Brand:ABB

Type:GRBTU 3BSE013175R1

Origin: the Swiss

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Are the Studio 5000 and RSLinx software installed? RSLogix and RSLinx are required to communicate to the CompactLogix or MicroLogix 1500-LRP processor.  How many words of data do you need to transfer in your application (from CompactLogix or MicroLogix 1500-LRP to Module / to CompactLogix or MicroLogix 1500-LRP from Module)?  Is this module replacing an existing legacy MVI69-MCM module (refer to section Legacy Mode on page 76)? 1.3 Package Contents The following components are included with your MVI69E-MBS module, and are all required for installation and configuration. Important: Before beginning the installation, please verify that all of the following items are present. Qty. Part Name Part Number Part Description 1 MVI69E-MBS Module MVI69E-MBS Modbus Serial Enhanced Communication Module 2 Adapter Cable Cable #14 RJ45 to DB9 Male Adapter cable. For DB9 connection to module’s serial application ports 2 Screw Terminal Adapter 1454-9F DB9 female to 9-pin screw terminal. Used for RS422 or RS485 connections to Port 1 and 2 of the module If any of these components are missing, please contact ProSoft Technology Technical Support for replacement parts.

Setting Jumpers When the module is manufactured, the port selection jumpers are set to RS-232. To use RS-422 or RS-485, you must set the jumpers to the correct position. The following diagram describes the jumper settings.

Note: Jumper pin placement on the circuit board may vary. The Setup Jumper acts as "write protection" for the module’s firmware. In "write protected" mode, the Setup pins are not connected, and the module’s firmware cannot be overwritten. The module is shipped with the Setup jumper OFF. If an update of the firmware is needed, apply the Setup jumper to both pins. The following illustration shows the MVI69E-MBS jumper configuration, with the Setup Jumper OFF.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now