Product Details

Dermatrix--non-invasive fractional RF equipment

Feature Skin Tightening, Acne Treatment, Skin Rejuvenation, Wrinkle Remover
Operation System High Frequency
Place of Origin Christmas Island
Brand Name GSD
Model Number GP699D

Product Features

Specifications

Dermatrix adopts non-invasive fractional RF to deliver heat energy deep into the subcutaneous layers to regenerate collagen, res

Dermatrix adopts non-invasive fractional RF to deliver heat energy deep into the subcutaneous layers to regenerate collagen, restore skin firmness and improve skin texture, producing the maximum dermal effects while minimize the damage to the epidermis. Obvious instant and long term skin rejuvenation result can be obtained after factional RF treatment.

 

 

Dermatrix--non-invasive fractional RF equipment

 

Technology Explanation

 

Fractional RF delivers accurate Bi-polar RF energy to the skin by a tip built of an array of small pins and return electrodes to create microscopic thermal zones (MTZ). The RF energy introduce fractional thermal into the deep dermis and create potential healing effects in the microscopic thermal zones. Undamaged tissue between the electrode pins acted as a “healing server” to accelerate the collagen rebuilding and skin tissues remodeling.

 

  

 

Unlike the traditional laser therapy, the majority of the fractional RF energy is focused in the dermis while only a small percentage of the surface is effected, resulting in deep volumetric dermal heating and ultimate result. On the contrary, laser stays large volume on the surface, while only a small amount of energy penetrates deep into the dermis.

 

 Dermatrix--non-invasive fractional RF equipment

 

Advantages

 

1 Four individual treatment programmes and instant feedback system

 

Four different treatment programmes(M1 M2 M3 M4) for different penetration depth are optional according to individua treatmentl requirement. No disruption to the surrounding normal skin area. Carefully selected energy level provides RF energy precisely targeting on exact layers.

                                    

Instant resistance feedback system ensures a safe, accurate and high-effective energy delivery. Energy will be output only when the resistance is normal. No energy output if the resistance is abnormal.

 

 

 

Dermatrix--non-invasive fractional RF equipmentDermatrix--non-invasive fractional RF equipment 

 

 

 

                                                                                  Normal                                         Abnormal

 

2 Optional tip types, disposable tip design to avoid cross infection

 

Two optional tip types, 64 pins(8*8)for deep-seated area treatment while 144 pins (12*12) for superficial area treatment. Suitable for both face and body treatment. Disposable tip for individual patient to avoid cross infection.

 

 

3 Treatment record management

 

A detailed record can be set up for each patient after every single treatment, including personal ID, treatment times, energy level, and remaining life span of each tip. Intelligent and comprehensive record offers a scientific reference to the following treatments.

 

 

4 Low complication risk, minimum downtime and no side effects

No limitation of skin types. The happening chance of pigmentation after treatment is lower compared to single-waved laser treatments. Minimum downtime, cosmetics are available after treatment and disturbance on daily life is minimal. No side effects.

 

5 Portable design and easy to use

Portable design and convenient for the users. 17 inch screen, simple and user-friendly interface.

 

 

6 Exclusive cosmeceutical set

 

Result could be optimized if combining with GSD Dermatrix exclusive cosmeceutical set. Specially designed post-treatment cosmeceutical accelarate the skin repairing and collagen regeneration process.

 

 

Applications

Pores reduction

Skin rejuvenation

Wrinkle reduction

Scars especially acne scars treatment

Skin laxity improvement

 

Comparison of similar technologies

Technology

Traditional RF

 

Fractional laser

Fractional RF

Ablative fractional laser

Non ablative fractional laser

Working mechanism

RF energy stimulate collagen regeneration and   subsequent tissue remodeling

Ablative fractional laser directing light column into selected area known as microscopic thermal zones, but the epidermis is entirely ablated. The surrounding undamaged skin tissue will accelerate the collagen remodeling.

 

Non ablative fractional laser directing light column into selected area known as microscopic thermal zones, while the epidermis stays fine. The surrounding undamaged skin tissue will accelerate the collagen regeneration..

Fractional RF deliver heat energy deep into the subcutaneous layers to regenerate collagen, producing the maximum dermal effects while minimize the damage on the epidermis.

Suitable skin type

Ⅰ-six

Ⅰ--four

 

Ⅰ—five

Ⅰ--six

Penetration depth

dermis

Epidermis and dermis

Epidermis and dermis

Epidermis and dermis

Clinic result

Skin rejuvenation,wrinkle reduction and skin tightening

Skin resurfacing

Skin rejuvenation,wrinkle reduction and scar improvement

Skin rejuvenation,wrinkle reduction,Pores reduction and scar improvement

Effectiveness

Medium

Good

Good

Excellent

Recovery time

No

23 weeks

710 days

1-3 days

Comfort

Comfortable

Painful

Less painful

Comfortable

Technical specifications

RF frequency

1.15MHZ

Total energy

Up to 142mj/pin

Treatment programme

M1 M2 M3 M4

Tip size

21*21mm

Tip pin

64 pins, 144 pins

Tip life span

500 shots

Screen size

17 inch LCD touch screen

Dimension

440mm*270mm*92mm

Net weight

8KG(without trolley)

 

 

 