Product Details

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

Place of Origin Shandong, China
Brand Name Winner
Model Number 2008

Product Features

 

Product Description

 

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

 Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

  

 Brief Introduction:

 

Winner2008 full automatic wet laser particle size analyzer measure size is from Namometer to millimeter. 

It use dual beam& multi spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field. It could be used to measure size of all  Non-metallic mineral materials.

 

 

 

Main Specifications:

 

 

Model Name

Winner2008A

Winner2008D

Standard

ISO13320-1:1999GB/T19077.1-2008Q/JWN001-2009

Measuring Range

0.01-2000μm

0.01-1200μm

Channels Number

127

127

Accuracy   

<1%   (Deviation of  D50 on national standard sample)

Repeatability 

<1%   (Deviation of  D50 on national standard sample )

Light source

Main: He-Ne laser (λ= 632.8nm,  P>4.0MW)

Auxiliary: Semiconductor laser:λ= 650nm,  P>10MW

Sample Pool

Volume:1L

Ultrasonic

Frequency:40KHz   Power:50W 

Stir

Revolutions Speed: 0-3000RPM (Adjustable)

Circulate

Rated Flow:30L/min    Rated Power:70W

Operation Mode

Full automatic software control

Optical Calibration System

Full automatic

TesSpeed

<2mins for each time

Volume

L104cW44cH54cm 

Net Weight

58Kg

 

Main Features:

 

1)Full built-in dispersion system set mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment. 

 

2) Optical Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state..

 

3)Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.

 

4)Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design and Dual-laser orthogonal light increase the measurement rang, and its precision achieves from 0.01 to 2000μm

  

 

Output parameters: particle size, particle distribution etc. D10, D 50,  D 90 and other customized parameters.

 

 Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

Packaging & Shipping

 

Wooden box package, G.W.:40KG.

We would ship machine by DHL, FeDex, China express, by sea and by air. 

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer 

 

 

Our Services

 Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

 Warranty: we will offer you free spare parts within 2 years, and technology support in all a life.

After warranty time, we will offer them at cost price, and shipping cost would be paid by customers. 

 

 

Certifications

 CE and ISO9001

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzerInstitute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

 

Company Information

 

Jinan Winner Particle Instrument Co., Ltd. have been specialized in particle size analyzer for more than 20 years since that we take National science Project-particle size analyzer development in 1985.

 

High quality assurance is our task and also what we are doing now. 

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

FAQ

 1. How about the package ? Is it safe during the delivery ? 

All Particle size analyzer is packed by standard strong wooden carton with foam inside.

It is safe when shipping. 

 

2. What is the delivery way ? How many days will the machine 

We will ship the particle size analyzer by DHL,FedEx, UPS,etc (Door to Door Service), around 5 days to arrive.

Or by Air to your airport (Door to Airport Service ), around 3 days to arrive. 

Or by Sea to the seaport,  Minium CBM requirement : 1 CBM, around 30days to arrive.

 

3. Do you provide the Warranty ? How about the after sales service ?

2 year warranty free for spare parts, Whole life technical support.

We have professional after sales team, if any question, assistant videos are also provided in after-sale service.

 

4, This machine is easy to use ? if I have no experience, I can also operate it well ?

Do you provide the user manual and operating videos to support us ?

Yes, our particle size analyzer is designed to use easily, computer control. Normally it will take you 2-3 hours to learn how to operate, if you are a technician, it will much faster to learn.

We will provide the English user manual for free , and the operation video is available.

 

5, If we come to your factory, if you will provide the free training ?

Yes, warmly welcome you to visit our factory, we will arrange the free training for you.

 

6. What is the payment way ?

We accept the payment terms: Bank transfer, Western union, Money gram, Paypal, etc.

 

If any question, you can send INQUIRY , or CHAT with us, we will be glad to service you !

 

Institute use Automatic Winner2008 Wide plastic particle size distribution laser particle size analyzer

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now