Product Details

Auto Ranging Manual Continuity Backlight Digital Multimeter

Place of Origin Shanghai, China
Brand Name ASTOR
Model Number 5-400308C
Measuring Current Range 200u/200mA
Measuring Voltage Range 500
Measuring Resistance Range 20M
Measuring Capacitance Range N/A
Measuring Inductance Range N/A
Operating Temperature 0 ~ 50 C
Dimensions 140 x 85 x 34 mm

Product Features

Auto Ranging Manual Continuity Backlight Digital Multimeter

 

 

 

Product Description

   

 

 

FunctionItem. 400308AItem. 400308BItem. 400308C
Count199919991999
BacklightN/AYesYes
Low Battery IndicatorYesYesYes
Overload indication11OL
Auto/ManualManualManualAuto
Auto power offN/AN/AYes
Data holdYesYesN/A
ACV200/500V
±(2.5%+5)
200/500V
±(2.5%+5)
500V
±(0.8%+5)
DCV200m/2/20/200/500V
±(1.2%+2)
200m/2/20/200/500V
±(1.2%+2)
500V
±(0.5%+5)
ACAN/AN/A200μ/200mA
±(1.5%+2)
DCA200μ/200mA
±(1.5%+2)
200μ/2m/20m/200mA
±(1.5%+2)
200μ/200mA
±(1.5%+2)
OHM200/2K/200K/2000KΩ
±(1.5%+2)
200/2K/20K/200K/2000KΩ
±(1.5%+2)
20MΩ
<1MΩ ±(0.8%+5)
>1MΩ ±(2%+5)
Continuity50 ± 25 Ω50 ± 25 Ω<50 Ω
Diode testYesYesYes
Battery test1.5/9/12VN/AN/A
TemperatureN/AN/A-40 ~ 752oF / -40 ~ 400oC
≤0oC (32oF ) ±(8%+8d)
> 0oC (32oF ) ±(1.2%+7d)
>100oC (212oF) ±(3%+3d)
Size: (L x W x H mm)140 x 85 x 34140 x 85 x 34140 x 85 x 34
Test Leads20AWG20AWG20AWG
Frequency Response50/60Hz50/60Hz50/60Hz
Working temperature

0oC ~ 50oF

32oC ~ 122oF

0oC ~ 50oF

32oC ~ 122oF

0oC ~ 50oF

32oC ~ 122oF
Battery life100 hours100 hours200 hours

 

 

 Auto Ranging Manual Continuity Backlight Digital Multimeter

SAFETY INFORMATION

To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, comply with the following parctices:

 

1. Before using the Meter, inspect the case. DO NOT use the Meter if the case is damaged.  Look for cracks or missing plastic parts. Pay particular attention to the insulation around the connectors.

 

2. Inspect the test leads for damaged insulation or exposed metal.  Check the test leads for continuity.  Replace damaged test leads before using the Meter.  Only test leads meeting ETL, cETL, CE, CAT III 600V, 1A can be used on this multimeter.

 

3. Verify a Meter's operation by measuring a known voltage.  DO NOT use the Meter if it operates abnormally.  Protection may be impaired. When in doubt, have the Meter serviced.

 

4.  DO NOT apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and earth ground.

 

5.  DO NOT measure voltages above 600 V in Category III installations

 

6.  DO NOT measure voltage when the function/range switch is set on the resistance (ohms) or the current (uA/mA) settings.  Never meausre current when the meter is set on the resistance range.  Never measure AC voltage when the meter is set on DC voltage or DC current settings.  Setting on the meter on the incorrect function may burn out some of the internal circuitry and may pose a safety hazard.

 

7.  Use caution when working eith voltages above 30V AC rms, 42 V AC peak, or 60 V DC.  These voltages pose a shack hazard.

 

8.  Use the proper terminals, function, and range for all measurement

 

9.  DO NOT operate the Meter around explosive gas, vapor, or dust.

 

10. When making connections, connect the common test lead before connecting the live test lead;  when disconnecting, disconnect the live test lead before disconnecting the common test lead.

 

11.  Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.

 

12.  For all DC functions, including manual or auto-ranging, to avoid the risk of shock due to possible improper reading, verify the presence of any AC voltages by first using the AC function. Then selet a DC voltage range equal to or greater than the AC range.

 

13.  Before measuring current, you should turn off power to the circuit before connecting the Meter to circuit.

 

14.  DO NOT operate the Meter with the case (or parts of the case) removed

 

15.  Use only two unchargeable 1.5V for Item 400308C or 9V for item 400308A/B batteries, properly installed in the Meter case, to power the Meter.

 

16.  Replace the battery as soon as the battery indicator appears with a low battery, the Meter mightr produce false reading that can lead to electric shock and personal injury.

 

17.  Remove test leads from the Meter before opening the Meter case or battery door

 

18.  When servicing the Meter, use only specified replacement parts.

 

                                 * * * Other Meters Available * * *

 

Mini Size Analog Multimeter

 

FunctionItem. 400305AItem. 400305BItem. 400305C
DC Voltage10/50/250/500 V50 V30 V
DC Volts Accuracy± 4% full scale
of range
± 4% full scale
of range
± 4% full scale
of range
AC Voltage10/50/250/500 V250/500 V150/300 V
AC Volts Accuracy± 5% full scale
of range
± 5% full scale
of range
± 5% full scale
of range
DC Current (mA)0.5/50/250 mAN/AN/A
DC Current Accuracy± 4% full scale
of range
N/AN/A
Resistance (Ohms)R x 1KN/AN/A
Resistance Accuracy± 4 arc of scale lengthN/AN/A
Continuity (audible)YesYesYes
Battery test1.5V, AA, AAA & 9V1.5V, AA, AAA, C, D,
&1.5V button cell & 9V
1.5V, AA, AAA, C, D,
&1.5V button cell & 9V
Decibels-20dB to +56dB on
AC voltage ranges
N/AN/A

 

Auto Ranging Manual Continuity Backlight Digital Multimeter

 

Digital Pocket Multimeter

 

FunctionItem. 400306AItem. 400306BItem. 400306C
Manual or AutoAutoManualAuto/Manual
Display Count200020002000
DC VoltsAuto Max 600V
± (0.5%+5dgt)
20V/200V
± (1.0%+5dgt)
Auto/Manual Max 600V
(1.5%+2dgt)
AC VoltsAuto Max 600V
± (0.8%+5dgt)
200V/500V
± (2.0%+10dgt)
Auto/Manual Max 600V
(2.3%+5dgt)
Resistance (Ohms)Auto Max 20MΩ
± (0.8%+5dgt) < 1MΩ
± (2.0%+5dgt) > 1MΩ
20MΩ/20KΩ/200Ω
± (1.5%+5dgt)
Auto/Manual Max 34MΩ
± (2.0%+5dgt) < 340KΩ
± (6.0%+4dgt) < 3.4MΩ
± (10.0%+5dgt) < 34MΩ
Diode testYesYesYes
Continuity (Audible)YesYesYes
DC Amps2000μA / 200mA
± (1.8%+5dgt)
N/AN/A
AC Amps2000μA / 200mA
± (1.8%+5dgt)
N/AN/A
Bettery TestN/A1.5VN/A
Input Impedance
(DCV Setting)
10M1M10M
Auto OffYesN/AYes
Data HoldYesYesYes
Max Data HoldYesN/AN/A
Bar GraphN/AN/AYes

 

Auto Ranging Manual Continuity Backlight Digital Multimeter

 

Digital Clamp Multimeter

 

FunctionItem. 400309AItem. 400309BItem. 400309C
Count199940004000
Analog Bar GraphN/AYesYes
BacklightYesYesYes
Low battery indicatorYesYesYes
Overload indicationYesYesYes
True RMS measurementN/AN/AYes
Auto/ManualAutoAuto/ManualAuto/Manual
Auto power off15 min15 min15 min
Data holdYesYesYes
RangeN/AYesYes
ΔZERON/AN/AYes
Max/MinMaxMax/MinN/A
ACV600V ±(1.0%+5)600V ±(1.0%+5)600V ±(1.0%+5)
DCV600V ±(0.8%+5)600V ±(0.8%+5)600V ±(0.8%+5)
ACA600A ±(2.0%+5)400 or 600A ±(2.0%+5)400 or 600A ±(2.0%+5)
DCAN/AN/A400A ±(2.0%+5)
OHM19.99MΩ ±(2.0%+5)40.00 MΩ ±(2.0%+5)40.00 MΩ ±(2.0%+5)
Continuity (audible)≤50Ω≤50Ω≤50Ω
Diode testYesYesYes
CapacitanceN/AN/A10.00nF~4000μF
±(4.0%+5)
Frequency counter10Hz~1999Hz
± 2.0%
10.00Hz ~ 9.999MHz
± 2.0%
10.00Hz ~ 9.999MHz
± 2.0%
TemperatureN/A752oF / 400oC
±(3.0%+5)
752oF / 400oC
±(3.0%+5)
Withstand Voltage6000V AC6000V AC6000V AC

 

Auto Ranging Manual Continuity Backlight Digital Multimeter

 

 

Our Services

Auto Ranging Manual Continuity Backlight Digital Multimeter 

 

Packaging & Shipping

Express Delivery:

  Auto Ranging Manual Continuity Backlight Digital Multimeter    Auto Ranging Manual Continuity Backlight Digital Multimeter          Auto Ranging Manual Continuity Backlight Digital Multimeter
    Auto Ranging Manual Continuity Backlight Digital MultimeterAuto Ranging Manual Continuity Backlight Digital Multimeter

Export Methods:

Air Freight      Ocean Freight
   Auto Ranging Manual Continuity Backlight Digital Multimeter 

 

 

 

FAQ

1.  What is your Payment Terms?

     A:  For first few trades:  30% Down payment ; balance T/T before shipment

          For trades after one year: 100% T/T before shipment 

          For trades after 3 years: Depending on the payment record, we can offer net 15 or net 30 Days

 

2.  What is your delivery time?

     A:  Normally it's 30 ~ 45 Days. During the busy months it will be 60 Days.  Please check with us.

 

3.  What is your MOQ requirement?

     A:  A shipment invoice over USD$5,000.00 to avoid a shipping & handing charge of USD$150.00. 

          To use your company color, the MOQ is normally above 1,000 or 2,000 pcs. Please check with us.

 

4.  Do you accpet placing LOGO on products?

     A:  Yes, there will be a MOQ requirement

 

5.  Do you offer exclusivity ?

     A:  Depending on the market you are in, pleaes check with us

 

 

Company Information

Auto Ranging Manual Continuity Backlight Digital Multimeter

Astor Industrial Corp. founded in 1979 specialized in Hand Tools, Garden Tools, and Electrical Items. Astor is also active in a variety of industries providing OEM solutions to our customers. Astor have 35 years of experience to provide Sourcing Services and Engineering Solutions which our engineers can assist you on your new product development.

With facilities in Taiwan, Hong Kong, and China, and an experienced staff versed in Western and Asian culture, Astor stands ready to serve your needs. Astor will help your company bypass the language barriers and time zone differences to perform contract negotiations, on-site inspections, and arrange shipment for your products.

Astor Industrial Corp. offers a complete program according to your demands. We hope to work with you in the very near future.

 

Welcome to Join US!

Feel free to contact us at your convenience

 

Auto Ranging Manual Continuity Backlight Digital Multimeter 

 

Final Reminder

 

Item No. 5-400308C
Sample time5~10days
Sample chargeYes
Sample freight costFreight collect

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now