NYSP-L861 Radio Frequency Admittance Switch

Place of Origin China
Model Number NYSP-L861

Product Features

Design features: It can be applied to the measurement of various conductive and non-conductive media.

Anti-adhesion: The use of patented anti-adhesion circuit can eliminate false signals caused by material adhesion.

Probe removable: There is no cable connection between the probe and the controller. The controller can be removed, replaced and repaired at any time without affecting the material output.

High and Low Temperature Resistance: Suitable for working environment from minus 184 degrees Celsius to 280 degrees Celsius. Ceramic probe for higher temperature can also be provided.

Output form: double-pole double-throw relay signal output, while the state lamp shows the output state, and from 0 to 30 seconds delay function

Intelligent diagnosis: After power-on, the instrument circuit automatically detects whether the working state is normal.

Typical applications: liquid, powder, particle, solid level control

Probe rod material: 304 + PTFE (optional)

Probe length: 500mm (customizable according to requirements)

Power supply: 24VDC, 220VAC (optional)

Process temperature: - 40 ~ + 130 degrees Celsius

Process Pressure: <2.0MPa

Process connection: thread and flange (optional)

Time delay: 0-30s adjustable

Loss Protection: Normally Open, Normally Closed, On-site Switchable

Output relay: DPDT output, 5A, 24VDC or 5A, 220VAC

Protection/Explosion Protection Level: IP67/Exia IICT6 (optional)