STM-8064G 980 laser spider vein removal / red blood silk removal / blood vessels removal
USD $1 - $2,000 /Unit
Min.Order:1 Unit
Guangzhou Shotmay Beauty Co., Ltd.
STM-8036M 6 big lipolaser + 4 small lipolaser slimming machine
STM-8036N 10 big lipolaser + 4 small lipolaser slimming machine diode laser
STM-8036M Lipolaser Lipo Laser Slimming Machine No Side Effects Fat Reduction with CE certificate
STM-8036M 2014 factory direct selling!!! newest vacuum rf lipolaser cavitation slim for wholesales
STM-8036M Home use 650nm 980nm dual band cold laser therapy machine lipolaser for wholesales
1.1. profile
Red blood is the reason for the exposure of capillaries and veins, which is also a major cause of skin thinning.
There are specialized to remove red blood laser procedures, for various reasons caused by capillary exposure
has the exact effect.980 cured red blood at the same time can stimulate the growth of collagen in the dermis
of the skin, increase the thickness of the skin and the density of the While the small vessels are no longer
exposed, the elasticity and resistance of the skin are also significantly enhanced.Time and energy conditions,
the small blood vessels to maximize the absorption of blood porphyrin, resulting in this small blood vessels,
the most Subsided, laser cured red blood will not damage the skin.
1.2 instrument introduction:
Laser cured red blood is the laser cured red blood instrument in the process of red blood treatment, the
introduction of the laser cured red blood instrument is dedicated to the red blood of the laser procedure and
for a variety of reasons caused by fine vessels revealed has an exact effect. The socalled red blood should
actually be known as telangiectasia, the principle of the expansion includes such as climate, high temperature,
low temperature, wind and sand, UV, glare
1.3 instrument structure:
The instrument is composed of three parts:
(1) the main body of the machine
(2) control panel
(3) optical fiber handle.
Inch Touch screen, you can choose a different mode of operation.
1.4 therapeutic range
1.4.1 genetic causes
Medical research has shown that 15% of the capillary dilation and genetic relationship is close, due to the
natural face of capillary blood In the process, it is easy to rupture of blood vessel wall, blood leakage, in the
skin surface can be seen a marked red blood Silk, as time goes forward, red blood will increase constantly
increased, and finally form a red pig ".
1.4.2 external causes
1) living in alpine areas or suffered frostbite, causing blocked blood circulation, blood vessel walls so that
the face stasis showing a red Blood.
2) after cosmetic skin repeatedly stimulate the dermal exposure to the outside to accept due to the strong
ultraviolet radiation of red Blood.
3) through the stratum corneum, damaged the surface of the skin, so that the skin becomes thin, red blood
cells are prone to leakage, the formation of surface The Department is red.
4) vascular aging, fragile, lack of flexibility, slow blood vessel contraction, red blood cells prone to leakage,
the formation of facial redness.
5) longterm use of corticosteroids, causing capillary dilation, resulting in thinning of the skin, shrinking and
so will cause the surface The Department is red.
The second chapter user notes
2.1 user notes
warning
If the improper operation of the instrument can cause skin burns, medical staff must be familiar with the
safety instructions and procedures before operation.Prior to use, the user must check the function of the
machine to eliminate the security threats caused by the patient and the three party.If the instrument is
connected to the peripheral equipment, it is necessary to read the instruction manual of the peripheral
equipment in detail.
2.1.1 safe operation
The design of the laser instrument is first considered from the safety of medical personnel and patients.
The following are the main security measures we take:
A: opens the processor, the processor will first make a self diagnosis. In the next treatment process will
continue to automatically detect the processor's internal system is operating normally.
B: turn the key to the left and turn the key switch when the instrument is needed to stop working.
2.1.2 security alert
It is only in the case that the Distributor agrees that the operator is able to repair the instrument's interior.
Any unauthorized disposal may cause damage to the instrument and cause the failure of the warranty.