Product Details

1-800ms CO2 Laser Beauty Machine For Women 808nm Diode Laser Permanent Hair Removal

Laser Type CO2 Laser
Q-Switch Yes
Style Stationary
Certification CE
Place of Origin Beijing, China
Brand Name Goldenlaser
Model Number GL016
Feature Blood Vessels Removal, Face Lift, Pigment Removal, Skin Tightening, Skin Rejuvenation, Wrinkle Remover, Acne Treatment

Product Features


Effective:

steady energy is achived by
a. Japan made Capacitors which stabilizes.

b. US made laser rod ensures 100,000,000shots.(every shot, steady energy)  but during our testing it went to 10 million shots.

c. 2 filters(one to filter out all impurities out of water to keep flow in high speed, and other preventing ion influx and decreasing the chances of laser bar damage.)

d. Japan made radiator tube , so water is always clean and flows fluently giving pleasant feelings while treatment.  

e. High speed DC pump made in germany, which keeps TEC chilled water flowing. 

f. 2 different power supplies , one for TEC cooling system and other for pump screen and other systems.



Specifications


2.CO2 Laser beauty machine

  CO2 Laser beauty machine for CO2 Laser beauty machine for 808nm diode laser permanent hair removal

 

1.Product parameters:

 


Application  

1. Remove all kinds of tattoo
2. Pigmentation removal,
 1). Epidermal pigment: Body tattoo , eye line and brow tattoo
 2). Vessels disease: Varicosity removal, capillary hemangioma
 3). Laser facial: Oil control, skin rejuvenation, skin pore improvement
 4).Dermal pigment: Nevus of ota, birthmark, coffee spot age pigment, freckle


Laser Type  

 co2 fractional laser

Wavelength

  10600nm

Beam Delivery   

  7-joint arm

Maximum Output Power

 35W/25W/15W (optional)

Optical Beam Quality   

TEM

Spot Size  

 0.12-1.25mm (Adjustable)

Power of the Aiming Beam 

<5mW

Aiming Beam  635nm

 635nm

Scanning Mode 

 Randomized Scanning

Laser Operating Mode l

 UltraPulse, CW, Fractiona

Cooling  

 Air Cooling

Pulse Energy 

 10mj~200mj (every stepping:2mj)

Spot Pattern  

Triangle/Square/Rectangle/Rhombus

Pulse Interval 

 1ms~100ms (every stepping:1mj)

Scan Area  

10mmx10mm,20mmx20mm,30mmx30mm

Working Mode 

Continuous operation

Spot Density  

 

36 spots/cm² , 144 spots/cm², 576spots/cm² with intermittent loading

Power Supply  

AC 220V 50Hz/AC 110V 60Hz

Gross Weight 

88KGS

Dimensions(before packaged) 

650mmx340mmx760mm

Dimensions (after packaged) 

760mmx455mmx975mm

 

2.Treatment Theory

 

Fractional laser light penetrates the skin with tiny thermal channels through the random scanning, creating an ablative and thermal effecton only channels (a micro-injury) without damaging the surrounding tissue. The tissue surrounding the micro-injury sites (about 15-20% of the treatment area) starts the process of healing. As collagen remodels, skin tightened, scars improved and pigmented lesions removed.

 

3.Application

 

(1). Application Range of Fractional treatment handpiece

a. Large pores, Fine lines, Skin tightening and whitening, Skin loosen(Deep Wrinkles), Stretch marks.

b. Various Scars: Burn Scars, Acne Scars, Surgical Scars and Keloid;


Treatment principle of 808nm diode laser hair remover:

Using thermal damage theory, the abundant melanin absorbs laser energy and the temperature rises rapidly, under this situation the hair follicle and hair shaft are damaged by thermal.

 At the same time, the oxygen supplying tissue surrounding the hair follicle’s stem cells is destroyed by the spreading heat energy.Thus hair regrowth is stopped permanently.

Treatment scope of permanent hair remover:

 All kinds of hair on body! Such as hair on face, around lip area, beard, underarm, legs,breast, bikini area Etc.


c. Reconstruction of photoaging skin.

(2). Application Range of Incision Handpiece

a. Via multiple handles it can be adapted to Gynecology, ENT, Neurology and general surgery

b. In cosmetic surgery, it can be adapted to incisions for Blephaplasty, Skin Tags and Ingrow Nails, Compound Nevus and Intra Dermal Nevus etc

 

4.GLO16 Advantages

 

(1)Three modes of laser energy output are selective: UltraPulse, CW and Fractional modes

(2)Adopt COHERENT RF-excited laser system enables the output quality more stable, more uniform, more consistent, (compared to ordinary CO2 laser installed with glass tubes)

(3)lHealing zone volume is adjustable, namely the volume of spots is adjustable in a certain healing zone. Therapists could adjust the spot density upon skin type, lesion parts and effectiveness requirement of different patients

(4)l Various spot volumes are suitable for different area of the body which maximally avoid the side-effect that result from the overlap of the spot, reduce the pain during the treatment, satisfy different therapiests' unique request. 

(5)12.1"  TFT touch LCD, rotated 360° gives you a luxury enjoyment;

(6)Reserved entry access for laser room ensures a safe treatment

(7)Comparing with existing traditional CO2 Sealed Glass Laser, RF excited CO2 lasts nearly permanently, therefore it deserves a higher initial cost which will be offset by a much lower total of ownership.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now