Parker AC890 Series-AC Variable-Frequency-Drive 890SD-532450D0-B00-1A000
USD $1000 - $2000 /Piece
Min.Order:1 Piece
Anhui TLDE Automation Technology Co., LTD
Parker AC890 Series-AC Variable-Frequency-Drive 890SD-532450D0-B00-1A000
Parker AC890 driver
The AC890 system driver is a modular AC motor driver performance unit that can be combined to form a complete multi-segment drive system that ses space, reduces wiring, and provides an excellent system. The safety torque switch function (PLE of the SIL3 or according to EN ISO13849 and EN 61800-5-2 classes) furnaces provides the framework.
The AC890 offers V/F, sensorless vector, closed-loop flux vector and servo position control, from simple AC motor control parts to more demanding parts. The AC890 comes in a wide variety of sizes and grades as well as input and output types, making it a solution for motion control projects.
The AC890 can be configured with five motor control modes
Open loop V/F control
This mode is suitable for basic speed control or multi-motor parallel control.
Sensorless vector control
With a cutting-edge sensorless vector algorithm, the AC890 delivers high starting torque and fast speed regulation without the need for any speed measuring devices.
Closed loop vector control
AC890 with encoder feedback option can achieve full closed loop flux vector performance. Provides full load static torque and high dynamic response speed loop. satisfy
Most of the application requirements.
PMAC servo control
Drive permanent magnet servo motor, such as TMW motor.
AFE, used for line regeneration
Using this configuration for situations where 4-Q or continuous braking is required, regenerative energy is returned to the grid, ensuring a power factor of 1 and a very low current harmonic content
(THD is less than 3%).
Compatible with various feedback devices
The AC890 is compatible with any AC motor and any speed/position feedback option. With this flexibility, you do not need to replace existing AC motors to achieve high performance
Please, se your time and money.
• Incremental encoder
• EnDat 2.1 (SinCos) encoder
• Rotary transformer
Performance level
The performance of AC890 inverter provides a level suitable for your application's needs. With 2 different performance levels, the AC890 system allows for flexibility of use.
Advanced performance
Basic links virtual machine feature blocks: mathematical functions, Boolean logic, timers, counters, plus: Motion adds a position loop, motion control function block control firmware, move increment, move, line drive main ramp and part control, (surface plasma we, coplanar weguide) winding machine block, fully functional PID, state machine, etc.
High performance
Advanced performance features, plus: Library pre-designed virtual dedicated connection feature blocks such as: shaftless printing, cut to Length, precision winding, trersal, etc.
Registration of shaftless printing control solutions
Printing mechanical row shafts easily replace personal AC890 drives, precise synchronization and the ability to print registers to adjust each section, guaranteeing alignment of each color. The AC890 High performance level features virtual machine functional modules in pre-designed specific segments of the application, including shaftless printing, cutting to length, precision winding, and more
Standard:
When installed in accordance with the relevant product manuals, the AC890 series is compatible with the following standards:
• CE Marked to EN50178 (Safety, Low Voltage Directive)
• CE Marked to EN61800-3 (EMC Directive)
• UL listed to US Standard UL508C
• cUL listed to Canadian Standard C22.2 #14
Technical specifications:
Main power supply:
3-phase
- 890SD : 380 - 500 VAC +/- 10 %, 50-60 Hz +/- 5%
- 890CS : 208 - 500 VAC +/- 10 %, 50-60 Hz +/- 5%
- 890CD : 320/560 - 705 VDC
- Frames E/F/G/H/J/K : 380 - 460 Vac +/- 10 %
Environment:
0-45°C (volume reduction 2%/°C up to its upper limit of 50°C)
Upper limit is 1000m ASL (capacity reduction 1% for each 100m increase, upper limit is 4000m)
product
brand
Parker
Product type
Ac driver
Drive shaft type
Uniaxial technique
Multiaxis technique
Product sequence
AC890
Input voltage
3*230VAC
3*380-480VAC
3*500-690VAC
320-705VDC (Public bus)
Output power
0.55-1200 kW
Compatible motor type
Brushless servo
Rimless servo
induction
Spindle motor
Torque motor
PMAC
Compatible feedback device
Rotary transformer
Increment encoder
Control mode
V / Hz
Sensorless vector
Closed loop vector
Active Front End
Speed control of permanent magnet motor
Communication interface
RS232 / RS485
CANopen
ControlNet
DeviceNet
Profibus
Profinet
Ethernet TCP/IP
Operating temperature
0-45 °C for Frames B-F/derate up to max 50 °C 0-40 °C for Frames G-K/derate up to max 50 °C
32-113F for Frames B-F (Capacity reduction, maximum allowable temperature 122F)
32-104F for Frames G-K (reduced capacity, maximum allowable temperature 122F) °F
Working height
Maximum 1000m ASL (Capacity reduction over 1000m)
Overload rating
Hey load (constant torque) : 150% lasts 60s
Standard load (variable torque) : 110% lasts 60s
Servo mode (Frames B-D) : 200% lasts for 4s
Servo mode (Frames E-J) : 150% lasts 60s
Conform to specifications
CE (EMC&LVD)
List by UL
Listed via cUL