Product Details

dc to ac power kit variable frequency delta vfd dc to ac inverter

Place of Origin Taiwan
Brand Name TOP GIN
Model Number TG300-B
Output Power Other, 2.2KW~75KW
Output Type Triple
Size 302*150*183(mm)~685*420*335(mm)
Weight 3KG~54KG
Input Voltage 380V
Output Voltage 380V
Type DC/AC Inverters
Output Frequency 400HZ
Output Current 4.2A-130A

Product Features

Pan-inverter

 

[Performance]

  • TG-300 IGBT inverter series, designed for industrial machinery, tools, machinery, high starting torque, smooth operation, the new generation of drive containing the PID controller design.

[Feature]

  • Automatic calculation of the load torque required to achieve the smooth start of the object.
  • High-speed precision, speed slip compensation function, to overcome load fluctuations caused by poor.
  • Precision sine wave control, current resembles current commercial motor running stable.
  • Can improve the motor running at light load efficiency to electricity saving effect.
  • Automatically adjusting motor operating voltage, the motor is maintained at the maximum-efficiency operation.
  • Embedded PID control software for flow, air flow control, etc., without external PID controller, suitable for wind, hydro-machine applications.
[ Specification ]
 
Control Characteristics
Control modeSine wave PWM mode
Frequency control range0.1~ 400Hz
Frequency accuracy (temperature change)Digital signal: ± 0.01% (-10 ~ + 40 ℃) analog signal: ± 0.1% (25 ℃ ± 10 ℃)
Frequency setting resolutionDigital signal: 0.1Hz analog signals: 0.06Hz / 60Hz
Frequency output resolution0.01HZ
overload150% of rated current 1 minute
Analog frequency setting signalDC 0~+10V (20KΩ),4-20mA(250Ω)
Deceleration time0.0 to 3600 seconds (acceleration, deceleration time set individually)
Brake torqueAbout 20% (125% loaded brake controller)
V / F curve15 kinds of fixed type, internal parameter setting adjustable V / F curve one
Protective function
Horse our protectionElectronic thermal relay protection
Instantaneous overcurrent200% of the rated current of the motor coasting stop
Fuse FusingProtectionFree running motor stops after the fuse blows
Kamakeno150% of rated output after 1 minute free-run stop
Overcurrent

220V class main circuit DC voltage of about 410V or more motor coasting stop
440V class main circuit DC voltage of about 820V or more motor coasting stop

Low Voltage

220V class main circuit DC voltage of about 190V motor coasting stop following
440V class main circuit DC voltage of about 380V motor coasting stop following

Momentary power failure compensationSetting when playing power outages than 15ms motor free run to stop (external capacitor to 2 seconds)
Heat dissipation piece overheatingThermistor protection
Stall preventionAcceleration and deceleration, stall prevention operation
Ground protectionElectronic circuit protection
Charging indicationMain circuit DC voltage above 50V indicator when charging "light"
Venues
VenuesThe room is not corrosive or dusty places
Ambient temperature- 10 ~ + 40 ℃ (lock wall type), - 10 ~ + 45 (within the disk take pay type) without a freeze condition
Storage temperature (* 2)-20 ~ + 60  ℃
HumidityBelow 90% RH (non-condensing conditions)
Vibration20Hz below 1G, 20 ~ 50Hz when 0.2G
Protective structureWall Mount locking plate inside and take pay type

 

[ SIZE ]

dc to ac power kit variable frequency delta vfd dc to ac inverter

dc to ac power kit variable frequency delta vfd dc to ac inverter

dc to ac power kit variable frequency delta vfd dc to ac inverterdc to ac power kit variable frequency delta vfd dc to ac inverterdc to ac power kit variable frequency delta vfd dc to ac inverterdc to ac power kit variable frequency delta vfd dc to ac inverterdc to ac power kit variable frequency delta vfd dc to ac inverter