1 Overview
1.1 Comprehensive Technical Characteristics of Frequency Converter
●Input-output Characteristics
◆ input voltage range: 380/220V±15%
◆ input frequency range: 47~63Hz
◆ output voltage range: 0~rated input voltage
◆ output frequency range: 0~400Hz
●Peripheral Interface Characteristics
◆ Programmable digital input: 7 inputs
◆ Programmable analog input: AI1: 0~10V input, AI2: 0~10V or 0~20mA input
◆Programmable open collector output: 1 output (open collector output or high-speed pulse output)
◆ Relay output: 2 outputs
◆ Analog output: 2 outputs, optional 0/4~20mA or 0~10V
●Technical Performance Characteristics
◆ Control mode: vector control without PG, V/F control
◆ Overload capacity: 150% rated current for 60s; 180% rated current for 10s
◆ Starting torque: vector control without PG: 0.5Hz/150% (SVC)
◆ Speed ratio: vector control without PG: 1: 100
◆ Speed control accuracy: vector control without PG: ±0.5% maximum speed
◆ carrier frequency: 1k~15.0kHz
●Functional Characteristics
◆ Frequency setting methods: digital setting, analog setting, serial communication setting, multistage velocity setting, simple PLC setting, PID setting and the like, and the combination and mode switch of these settings can be realized.
◆ PID control function
◆ Simple PLC, multistage velocity control function: 16-stage velocity control
◆ Swing frequency control function
◆ The function of momentary power interruption but not shutdown
◆ JOG key function: multi-functional shortcut key defined by the user freely
◆ Automatic voltage regulation function: being capable of keeping constant output voltage automatically in case of network voltage change
◆Providing various fault protecting functions: the functions of protection against over current, overvoltage, under voltage, over temperature, phase loss, overload and the like
Machine Parts
Name: E302
Brand: olu
Original: China
Main Features
Name: E301
Brand: olu
Original: China
Machine Parts
Name:Peripheral Equipment Connection Diagram
Main Features
Name: Description of Major Loop Terminal Block
The three-phase major loop terminal block distribution diagrams are shown in figures 4-2 (a-d), and the instruction on the functions of various terminals is shown as follows.
a) The Major Loop Terminal Block Distribution Diagram of 0.75KW-22KW Frequency Converter (as shown in fig. 4-2a)
b) The Major Loop Terminal Block Distribution Diagram of 30KW-37KW Frequency Converter (as shown in fig. 4-2b)
c) The Major Loop Terminal Block Distribution Diagram of 45KW-110KW Frequency Converter (as shown in fig. 4-2c)
d) The Major Loop Terminal Block Distribution Diagram of 132KW-315KW Frequency Converter (as shown in fig. 4-2d)
Products Name with link
91.8% Response Rate
Products Name with link
91.8% Response Rate
Products Name with link
91.8% Response Rate