DTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tube

Place of Origin Beijing, China
Brand Name DTEC
Model Number XXH-3005

Product Features

Product Description

XXH-3005 Portable Gas-filled X-ray Flaw Detector comes with 300kv output tube voltage, 5mA maximum tube current and flat target, panoramic glass X-ray tube, with characteristic of auto self-test and anti-jamming.


Equipment Structure:
Each model of X-ray equipment is composed of the controller, X-ray generator, power cable, connecting cable and cable accessories.

  • Controller
DTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tube
The controller is shaped like a suitcase. All operative buttons are furnished on the front panel while the cable port, main switch and grounding terminal are located inside the control box on the right side of it. The schematic drawing of the controller refers to the Drawings.
The controller includes the parts as below internally:
A. kV control board; 
B. mA control board; 
C. Microprocessor control board;
D. Protective circuit board;
E. SCR Voltage-regulation modules;
F. LC filter;
G. Primary and secondary SCR inverter system; 
H. Cooling fan;
  • X-ray Generator

     Main Panel

DTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tubeDTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tube

 

 

The X-ray generator is of the module type. The X-ray tube, HV transformer and insulated gas (SF6) are encapsulated in an aluminum shell of sylindrical shape. The fan and heat radiator are mounted on one end of the X-ray generator. When the warning lamp lighting on, it means the X-ray NDT equipment is under the stand-by condition and X-ray will be produced (The warning lamp keeps lighting on in the whole course of producing the X-ray). The schematic drawing of the controller refers to the Drawings.
The X-ray generator mainly includes the parts as below
A. X-ray tube; 
B. HV transformer; 
C. Temperature relay;
D. Pressure meter for gas;
E. Socket for connecting cable;
F. Warning lamp;
G. Cooling fan for the X-ray tube; 
H. Charge and discharge valves for gas.

 


DTEC Advantages

 

  • Automatically Checking the software and hardware after starting the machine;
  • Excellent anti-jamming performance, which is suitable for field operation without power supply, due to the motor support;
  • Adjustable of exposure parameters with keys (easy operation);
  • Function of delaying to open HV, convenient for operator to keep away from dangerous field;
  • Adjustable of high voltage slowly for protecting X-ray generator;
  • Automatically controlling according to 1:1 working and rest operating mode, the longest continuous exposure period is 5 minutes;
  • Complete protecting system included: over KV, low mA, over mA, over temperature and optical-sound alarming;
  • Convenient for repairing and maintenance;
  • Much more Substance for structure designing, much more convenient for local operation;
  • Time can be changed for±0.3 according to the power supply net to make the exposure more precise.

Specification

 

Model
100KV
160KV
200KV
250KV
300KV
350KV
Power Supply
AC220V±10%  50MHz
Max. Tube Current
5 mA
Power (kW)
>1.0
>1.5
>2.0
>2.5
>3.0
>3.5
Tube Voltage (kV)
40-100
60-160
80-200
130-250
150-300
200-350
Focal Spot (mm)
XXQ
1.0x1.0
1.5x1.5
1.5x1.5
2.0x2.0
2.5x2.5
2.5x2.5
XXG
 
2.0x2.0
1.5x1.5
1.5x1.5
2.5x2.5
2.5x2.5
XXH
1.0x1.5
1.0x2.0
1.0x2.0
1.0x2.4
1.0x2.5
1.0x2.5
XXHA
 
1.0x3.5
1.0x3.5
1.0x5.0
1.0x6.0
1.0x6.0
Generator (KG)
XXQ
10
15
23
35
43
44
XXG
 
14
25
31
37
38
XXH/XXHA
11
15
22
31
41
44
Controller Weight
13KG
Radiation Angle
XXQ
40°
XXG
40°
XXH
360°x25°
XXHA
360°x40°
Max. Penetration (mm)   (A3Steel)
XXQ
8
20
29
39
49
59
XXG
 
20
29
39
49
59
XXH
6
18
26
36
46
55
XXHA
 
15
24
34
40
50
Insulation
SF6 Gas
Environmental Temperature
-25℃-40℃
Relative Humidity
No more than 85%
Working Conditions of X-ray Photography
1. Focus to Film: 600mm
2. Exposure time: 5 min.
3. Film: TianJin, Model III, intensified by double lead foil.
4. Treatment in the darkroom: Temp. 20 ±2ºC, 5 min. blackness ≥ 1.5
Safe Working Pressure
for Gas
0.35 ~ 0.50 MPA
(Operation will be prohibited in the case less than 0.35 MPA)

 

 

 

Packing List & Accs

  Standard Packing List:


Items
Qty.
Note

X-ray Generator

1 Pcs.

Flat Target, Panoramic Glass X-ray Tube

Controller
1 Set
 

Connecting Cable

1 Pcs.

10 Cores, 25M

Power Cable
1 Pcs.
2 Cores, 10M
Grounding Wire
1 Pcs.
5M
Fuse
5 Pcs.
20A
Fuse
5 Pcs.
3A

Alarm Lamp

1 Pcs.
 

Film dark cassettes

5 Pcs.
 

Intensifying Screen

5 Pcs.
 

Wire Penetrameter

1 Set
IQI
 

 

 

 

Packaging & Shipping

Every set of our equipement will be carefully tested and double checked steps by steps before being packed and delivery,as we all know that among such fierce international competition,only 100% good quality and stable performance can finally attain the customer's trust.Hence,we will always put the equipment calibraton job in the first place while manufacturing.

 

DTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tubeDTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tubeDTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tubeDTEC XXH-3005 Portable Gas-filled X-ray Flaw Detector,with flat target, panoramic glass X-ray tube

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now