Product Features

Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
-Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
-Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
-Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
-Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.
Product Description
Air Source Heat Pump Electrical Load Specification
ModelRF8I/bdmRF12I/bdmRF13I/bdmHF20I/bdm
Rated HeatingHeating capacitykW9151820
Power inputkW2.594.315.145.81
COPW/W3.473.483.53.44
Heating capacitykW5.5310.512.114.5
Nominal Heating
Power inputkW2.344.435.136.01
COPW/W2.362.372.362.41
IPLV(H)W/W2.82.852.852.86
Low Temp. Heating
Heating capacitykW4.58.910.112.5
Power inputkW2.344.565.15.95
COPW/W1.921.951.982.1
Rated CoolingCooling capacitykW811.512
Power inputkW3.24.64.8
EERW/W2.52.52.5
Power SupplyV/Ph/Hz220/1/50
Max. Power Input (With E-Heater)kW4.4(+3)5.2(+3)6.6(+3)7.1(+3)
Max. Current InputA20(+13.6)23.7(+13.6)30(+13.6)32.5(+13.6A)
(With E-Heater)
Max. Water Temp.58
(Without E-Heater)
Working Range-30 to 43-35 to 43
(Ambient temp.)
Refrigeration CirculationRefrigerantTypeR410A

Qty./Kg1.73.153.153.15
CompressorQty.1

TypeDC INVERTER DOUBLE ROTOREVIDCINVERTER
DOUBLEROTOR
EvaporatorTypeHigh efficiency hydrophilic aluminum foil fin heat exchanger
EEVTypeElectronic Expansion Valve

Qty.12
Fan Motor

Power1402*150
Input(W)
Fan Blades SizemmΦ560*139Φ525*135
Liquid valve sizeinch(mm)3/8"(9.52)
Gas valve sizeinch(mm)5/8"(15.88)
Water SystemCondenserTypeTube in tube heat exchanger
Water PumpTypeShielded pump
Water Flowm³/h1.381.982.062.5
Water Dropkpa35353848
Air Vent ValveTypeStandard
Pressure Release ValveTypeStandard
Pressure3kgs
value
E-HeaterkW3
Buffer TankL5
Water Inlet/Outletinch(mm)5/4" male
Pipe Size
Net Dimensionsindoor Unitmm760x510x330
(L*W*H)
Outdoor Unitmm947x403x813940x393x1373
(L*W*H)
Package Sizeindoor Unitmm795x562x373
(L*W*H)
Outdoor Unitmm1050x468x8471060x490x1395
(L*W*H)
N.W.Indoor Unitkg43
Outdoor Unitkg63110115
G.W.Indoor Unitkg48
Outdoor Unitkg70125130
Noise
Level
Indoor UnitdB(A)≤35
Outdoor UnitdB(A)≤59.5≤61.5≤62

Air energy heat pump is to use the heat in the air to generate heat energy, can 24 hours a day, high water pressure, constant temperature to provide the whole family with different hot water, heating and cooling needs, and at the same time to consume the least energy to complete the above requirements.

The principle

Air energy heat pumps operate on the "reverse Carnot" principle, the reverse Carnot cycle principle. Operating through a compressor system, it absorbs heat from the air to produce hot water. The specific process is: the compressor compresses the refrigerant, the temperature rises after compression, and the refrigerant passes through the condenser in the tank to produce hot water. The refrigerant after heat exchange returns to the compressor for the next cycle. In this process, the air heat is absorbed into the refrigerant through the evaporator, and the refrigerant is introduced into the water to produce hot water. Air heat pump water heater is a new generation of water heater which is heated by compressor air. Metaphorically speaking, the "outdoor machine" compresses the air like a pump, raising the temperature of the air, and then conducts heat to the indoor water storage tank through a liquid that will boil at -17 ° C, and then releases heat to the water.

The heat pump works on the principle of heating, as opposed to air conditioning refrigeration - the national refrigeration standard is 1000 watts, and electric refrigeration is 2800 watts. According to the principle of heat balance, at least 2800 watts of heat is generated at the same time, plus the input of 1000 watts of electricity, the actual heat generated in 3000- 4000 watts, the heat is transported to the insulated water tank, its power consumption is only a quarter of the electric water heater (even if the thermal efficiency is 100%, the input of 1000 electricity is only 1000 watts of heat).

Air-powered water heaters do not require sunlight, so they can be placed at home or outside. Therefore, most of the manufacturers of the machine have a separate machine and a machine, solar water heater storage after the water is used up, it is difficult to immediately produce hot water. If the electric heating takes a long time, and the air heater as long as there is air, the temperature is above zero degrees Celsius, it can operate 24 hours a day under pressure. In this way, once a tank of water is used, another tank of hot water will be produced in an hour or so. At the same time, it can fundamentally eliminate the electric water heater leakage, dry burning and gas water heater when the use of harmful gas and other safety hazards, overcome the solar water heater overcast and rainy days can not be used and installation inconvenience and other shortcomings, with high safety, high energy saving, long life, no gas emissions and many other advantages. Air energy water heaters generally have a life span of 10 to 15 years.