Portable oil dissolved gas analysis device (DGA 2013-1), gas chromatography system, auto gas analyzer, LCD display
Negotiable
Min.Order:1
Portable oil dissolved gas analysis device (DGA 2013-1), gas chromatography system, auto gas analyzer, LCD display
Application
DGA2013-1 adopts dissolved gas chromatorgraphy analysis system,runs by computer automatic control, all-keyboard operation and large-screen liquid crystal display according to the requirements of power system Dissolved Gas Component Determination In Insulation Oil (chromatography), and is characterized by high-precision temperature control, stable and reliable performance, high sensitivity, good reproducibility etc.
It adopts double-pillar parallel shunt system ,equipped with TCD, double FID and methane conversion oven, and could achieve total analysis of nine components (H2,O2,N2,CH4,C2H2,C2H4,C2H6,CO, CO2)of dissolved gas in insulation oil by one time.
It can be employed for internal fault detection of power system oil and gas equipments, cooling medium analysis of hydrogen-cooled generators, impurity analysis of sulfur hexafluoride, the boiler flue gas analysis, gas analysis and environmental monitoring analysis. Due to its employment not only for special analysis, but also for general analysis, the analyzer becomes the most effective gas analytical instrument in petroleum, chemical engineering, mining and other systems.
Major charateristics:
1. Computer-keyboard operation,easy to operate.
2. High precision and sentivity,good reproducibility
3. Stable and reliable analyzing performance
4. Automatic analysis process,simple operation
5. Large LCD screen
Major technical parameters:
1.Temperature control
1.1 Temperature range
Column chamber: room temperature +15°c---399 °c
Vaporizing chamber: room temperature+30 °c —399 °c
Conversion furnace :room temperature+30 °c —399 °c
Thermal conductivity detector: room temperature+30 °c —399 °c
Hydrogen flame detector :room temperature+30 °c —399 °c
1.2 Temperature control precision: ±0.1 °c
2. Thermal conductivity detector
2.1 Sensitivity: minimum detectable concentration of hydrogen≥5μl/L
2.2 Noise: ≤0.05mv
2.3 Drift: ≤0.15mv/30min
3. Hydrogen flame detector
3.1 Minimum detectable concentration of hydrocarbon≥5μl/L
3.2 Minimum detectable concentration of CO,CO2≥5μl/L
3.3 Noise: ≤0.05mv
3.4 Drift: ≤0.15mv/30min
You may also insterested in our transformer oil breakdown voltage tester and mositure tester.
Our Testing Equipements:
1.Transformer oil breakdown voltage tester ( BDV test kit) series IIJ-II
2. Acidity tester model ACD-3000I
3. Karl Fischer water content tester model TP-6A / model TP-2100
4. Moisture content tester(TPEE)
5. Fully automatic interfacial tension analyzer model IT-800
6. Gas-chromatography transformer oil gas analyzer model DGA2013-1
7. Consolidation point determinator model PT-2000
8. Kinematic viscosity tester model VST-2000
9. Flash point tester (open cup) model TPO-3000
10. Flash point tester (close cup) model TPC-3000
11. Transformer tester (CT/PT tester) model TPVA-404
12. Transformer turn ratio tester model HYG-II
13. Total base number analyzer(TBN tester) TBN-2030
For more information, contact us please.