Product Details

DW-GC1290 High Quality Gas Chromatography System For Laboratory

Brand Name Drawell
Place of Origin Shanghai, China

Product Features

Product Description

DW-GC1290 Gas Chromatography

Features:
★Control system: designed for monitoring and controlling the instrument via the computer. ★Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by “control system”) ★Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control ★Column oven supports quick heat-up and rapid cool-down with automated back-door opening. ★Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control. ★High sensibility and stability detector. ★2 independent and analog signals output. ★M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Electronic pneumatics control system
Flow rate: 200ml/min (N2), 1000ml/min (He) Flow rate accuracy: ±5% Flow rate repeatability: ±0.35% Split ratio: 0-5000(He), 0-1000(N2) Inlet temperature: 0-420℃

Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector Carrier Gas System: air source/ purification and desiccation device/ flow rate control device Sample Introduction System: sample injector Separation System: chromatographic column(packed column and capillary column) Temperature Control System (Column Oven): constant temperature and programmed temperature Detector: FID/ FPD/ NPD

Advanced Microcomputer Control System
★Superior performance with advanced, microcomputer-based temperature control system
★High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference ★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.) ★Intuitive display of timing program, detector status, measurement range, current setting, etc
Model#
DW-GC1290
Description
EPC(electronic pneumatic control)
7 inch touch screen display
Sample Introduction System
sample injector and evaporation chamber
Column Oven
Temperature range
Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
Temperature accuracy
± 0.02℃
Cooling time
350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1℃~80℃/min (in 1℃ increment)
Program ramps
20 ramps in total (99 ramps available with control workstation)
Size (L*W*H)
284*280*241mm(inside)
340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit
≤8×10-12g/s (n-hexadecane)
Drift
≤1.5×10-13A/h
Noise
≤3×10-14A
Linearity range
≥106
Flame Photometric Detector
(FPD)
Detection limit
≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S)
Drift
≤2×10‐11A/30min
Baseline noise
≤5×10‐12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit
≤5×10-12g/s(N) (Azobenzene)
≤5×10-13g/s(P) (Malathion)
Packing & Delivery