Product Details

DMF-Series Medium-Small Mass Flow Meter

Place of Origin Beijing, China
Brand Name Sincerity
Model Number DMF-Series

Product Features

Product Name: DMF-Series Medium-Small Mass Flow Meter
Product Description

 

Technical Parameters: 

Applications                                                                                                       Suitable for Liquid, Gas, Liquid- Solid, Gas- Solid, Liquid- Gas Mass Measurement or volume measurement
Material of the Measurement PipelineSS 316L/ HC Hastelloy
PressurePlease refer to the chart shown below. Special orders would be placed for high pressure.
Medium Temperature-50℃~+150℃ (Highest Temperature: +350℃, Lowest Temperature: -300℃ could be special ordered ) 
Environment TemperatureSensor:-40℃~+150℃; Transmitter:-20℃~+70℃
Flow Rate Measurement Accuracy± 0.2% ,± 0.1% optional
Density Measurement Accuracy±0.002g/cm³,±0.001g/cm³ optional
Repeatability±0.10% Flow Rate ±[½(Zero Point Stability/Flow Rate)×100]% Flow Rate
Output Signal

4~20mA   Load Resistance <500Ω(Instantaneous or Density optional);

0~10kHz  Instantaneous Flow Rate Pulse Signal;

Standard RS 485 RTU protocol 

Explosion- Proof SymbolEX d ib  II C T5 Gb

 

Micro Coriolis Mass Flow Meters: DMF-1-1; DMF-1-2

 

Model

DN

Measurement scope(kg/h)

Work Pressure (MPa)

Connection type (mm)

DMF-1-1-AB

1.5

0~4

0~32

Weld Joints Φ6×1.5

DMF-1-1-A

3

0~40

0~32

Weld Joints Φ6×1.5

DMF-1-1-B

6

0~100

0~25

Weld Joints Φ10×2

DMF-1-2-A

8

0~200

0~20

Weld Joints Φ10×1

 

High Pressure Medium Scale Coriolis Mass Flow Meters: DMF-1-3; DMF-1-4; DMF-1-5-A

Model

DN

Measurement scope (kg/h)

Work Pressure (MPa)

Connection Type(mm)

DMF-1-3-A

10

0~500

0~25

Weld Joints Φ20×4

DMF-1-3-B

15

0~1000

0~25

Weld Joints Φ20×3

DMF-1-4

20

0~3000

0~25

Weld Joints Φ20×2

DMF-1-5-A

25

0~10000

0~25

Weld Joints Φ31×3

 

 

Large-scale Flow Meter: DMF-1-3; DMF-1-4; DMF-1-5; DMF-1-6

High pressure could be special ordered. (4~70MPa) 

Model

DN

Measurement scope (t/h)

Work Pressure (MPa)

Connection Type(mm)

DMF-1-3-A

10

0-0.5

0~4

Flange 10

DMF-1-3-B

15

0-1.0

0~4

Flange 15

DMF-1-4

20

0-3.0

0~4

Flange 20

DMF-1-5-A

25

0-10

0~1.6

Flange 25

DMF-1-5-B

40

0-20

0~1.6

Flange 40

DMF-1-6-A

50

0-30

0~1.6

Flange 50

DMF-1-6-AB

65

0-50

0~1.6

Flange 65

DMF-1-6-B

80

0-100

0~1.6

Flange 80

DMF-1-6-C

100

0-150

0~1.6

Flange 100

DMF-1-6-CD

125

0-200

0~1.6

Flange 125

DMF-1-6-D

150

0-300

0~1.6

Flange 150

DMF-1-6-E

200

0-500

0~1.6

Flange 150

 

DMF-V-Series Coriolis Mass Flow Meters

 

Model

DN

Measurement scope(T/h)

Work Pressure (MPa)

Connection type (mm)

DMF-1-3-V10

10

0-1.0

0~4

Flange DN10

DMF-1-3-V15

15

0-3.5

0~4

Flange DN15

DMF-1-4-V20

20

0-5.5

0~4

Flange DN20

DMF-1-5-V25

25

0-15

0~4

Flange DN25

DMF-1-6-V50

50

0- 40

0~4

Flange DN50

DMF-1-6-V80

80

0- 100

0~1.6

Flange DN80

DMF-1-6-V100

100

0- 150

0~1.6

Flange DN100

DMF-1-6-V150

150

0- 350

0~1.6

Flange DN150

DMF-1-6-V250

250

0- 500

0~1.6

Flange DN250

 

 

 Product Details:

DMF-Series Medium-Small Mass Flow Meter

DMF-Series Medium-Small Mass Flow Meter 

 

Company Information

 

DMF-Series Medium-Small Mass Flow Meter

 

Beijing Sincerity Automatic Equipment Co,. Ltd is the manufacturer of producing Coriolis Mass Flow Meters. Our company was reformed from the China Petroleum &Chemical Corporation's Beijing Research Institute of Chemical Industries in 2006.

 

We have particular professional formula to produce the measuring pipeline compared to the other producing factories. Zeropoint Stability is good. Medium with tiny flow rate could be measured precisely, which reaches a minimum of 0- 1kg/h. Gas with either low pressure or with high pressure could be measured as well. Give us your problems, and you will never be disappointed!

 

Product Line:

DMF-Series Medium-Small Mass Flow MeterDMF-Series Medium-Small Mass Flow Meter

DMF-Series Medium-Small Mass Flow Meter

 

DMF-Series Medium-Small Mass Flow Meter 

Packaging & Shipping

 

Package: 

The Normal Package is Carton Package. 

While the wooden box package could be special ordered. All of these are plywood boxes with IPPC mark.

And this packaging standard is the same with the imported brand, such as Siemens, etc.  

DMF-Series Medium-Small Mass Flow MeterDMF-Series Medium-Small Mass Flow Meter

 

 

 

FAQ

 

Q: Why choosing Coriolis Mass Flow Meters but not the other flow meters?

 

A:

 

Coriolis mass flow meters has huge difference with the volumetric flow meters.

 

All the other flow meters except the Coriolis mass flow meters could be called as volumetric flow meters, including, turbine flow meters, thermal mass flow meters, vortex flow meters, electromagnetic flow meters, etc.

 

For the Coriolis Mass Flow meters:

  1. The measurement of the Coriolis Mass Flow meters will NOT be influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation is NOT required.
  2. The accuracy of the Coriolis Mass Flow Meters is ±0.1%, ±0.2% . The accuracy will NOT be influenced by the factors mentioned above.

Compared to this,

For the Volumetric Flow Meters:  

  1. The measurement of the volumetric flow meters WILL BE influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation IS REQUIRED.
  2. The accuracy of the volumetric flow meters  is said to be reached by ±0.5%. While, the actual accuracy is hard to reach this level of ±1%. The accuracy will be influenced by factors as mentioned above.

 

 

 