Product Details

ul listed fire sprinkler fire for automatic sprinkler system

Place of Origin Fujian, China
Brand Name OEM
Model Number ZSTZ&ZSTX&ZSTBS&ZSTP

Product Features

ul listed fire sprinkler fire for automatic sprinkler system

 

Product description

1. Brief introduction:

Glass bulb fire sprinklers, which is the key part of automatic sprinkler sytem, can be used to not just detect fire risk but control the fire and extinguish it by automatically spraying water. Since it can meet the requirements of protection from fire risks at degrees, glass bulb sprinklers are generally used in high buildings, hotels, department stores, and warehouses, etc.

The environment temperature of working is not less than 4 ℃, and is not higher than 70 ℃.

2. Composition and structure:

Made of brass frame, splash, deflector, glass ball, seals, tight set screws.

3. Operating principle:

Spray Sprinklers serve a variety of applications but all operate individually when heat at the sprinkler is high enough to "automatically" operate a calibrated thermal link that opens the sprinkler allowing the pressurized water to spray onto the source of heat. If the first sprinkler cannot control the fire the heat will build and spread to adjacent sprinklers that will operate as needed. Although special situation/applications use sprinkler heads or nozzles that are already open such that water discharges through all the sprinklers at once, the normal "Wet" Pipe system limits the water flow to the area of high heat.

4. Technical parameters:

Sprinklers vary considerably in their water flow characteristic since they are each designed for certain applications, however their basic shapes are limited to Uprights, abbreviated SSU (vertical above pipe, spraying down), Pendants, abbreviated SSP (vertical, below pipe spraying down) and Sidewalls, Horizontal (abbreviated HSW) and Vertical (VSW), both spraying horizontally. 

Technical parameters

Type

Nominal diameter(mm)

Connecting thread

Flow coefficient

T-ZSTP

Conventional sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTX

Pendent sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTZ

Upright sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

T-ZSTBS

Sidewall sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

ZSTDY

Concealed sprinkler

DN15

R1/2

80±4

DN20

R3/4

115±6

 

 Glass bulb technical parameters

Rated operating temperature

Max.ambient temperature

Glass bulb colour

57

27

Orange

68

38

Red

79

49

Yellow

93

63

Green

141

111

Blue

182

152

Purple

 5. Product photo:

1.  CCC/UL Listed fire sprinkler

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

  • Model: GW001 ZSTZ
  • Style: Upright fire sprinkler
  • Size: NPT/BSP R1/2" or R3/4"
  • Material: Brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure: 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature :57°C/68°C/79°C/93°C/141°C
  • Model:GW002 ZSTX
  • Style: Pendent fire sprinkler
  • Size: NPT/BSP R1/2" or R 3/4"
  • Material: Brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure : 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature :57°C/68°C/79°C/93°C/141° C 
  • Model:GW003 ZSTBS
  • Style: Sidewall fire sprinkler
  • Size: NPT/BSP R1/2" or R 3/4"
  • Material: Brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure : 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature :57°C/68°C/79°C/93°C/141°

2. Viking type fire sprinkler

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

  • Model: VK001
  • Style: Upright fire sprinkler/SSU
  • Size: NPT/BSP R1/2" or R3/4"
  • Material: Natural brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure : 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature : 57°C/68°C/79°C/93°C/141°C

 

  • Model: VK002
  • Style: Pendent fire sprinkler/SSP
  • Size: NPT/BSP R1/2" or R3/4
  • Material: Brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure : 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature :57°C/68°C/79°C/93°C/141° C 

 

  • Model: VK003
  • Style:Sidewall fire sprinkler/HSW
  • Size: NPT/BSP R1/2" or R3/4
  • Material: Brass
  • Plating: Chrome, Natural brass, White, or customized
  • Working pressure : 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature : 57°C/68°C/79°C/93°C/141° C 

 

3. TYCO type fire sprinkler

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system 

 ul listed fire sprinkler fire for automatic sprinkler system

  • Model: TY001
  • Style: Upright fire sprinkler/SSU
  • Size: NPT/BSP R1/2" or R3/4"
  • Material: Brass
  • Working pressure: 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature: 68°C
  • Model: TY002
  • Style: Pendent fire sprinkler/SSP
  • Size: NPT/BSP R1/2" or R3/4"
  • Material: Brass
  • Working pressure: 1.2Mpa
  • K-factor: 5.6/11.2
  • Operating temperature: 68°C 
  • Model: TY003
  • Style: ESFR U/ ESFR P
  • Size:  NPT/BSP R3/4" or R1"
  • Material: Brass
  • Working pressure: 1.2Mpa
  • K-factor: 11.2/25.4
  • Operating temperature : 74°C 

4. GLOBE type fire sprinkler

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

ul listed fire sprinkler fire for automatic sprinkler system

  • Model: GL001
  • Style: Upright fire sprinkler/SSU
  • Size: 1/2"
  • Material:Brass
  • Plating: Brass or Chrome
  • Working pressure:1.2Mpa
  • K-factor: 5.6
  • Working tempreature: 68℃

  • Model: GL002
  • Style: Pendent fire sprinkler/SSP
  • Size: 1/2'
  • Material: Brass
  • Plating: Brass or Chrome
  • Working pressure:1.2Mpa
  • K-factor: 5.6
  • Working temperature: 68℃

  • Model: GL003
  • Style: Sidewall fire sprinkler
  • Size: 1/2'
  • Material: Brass
  • Plating: Brass or Chrome
  • Working pressure:1.2Mpa
  • K-factor: 5.6
  • Working temperature: 68℃

3.Other products recommendation

 ul listed fire sprinkler fire for automatic sprinkler system

 ul listed fire sprinkler fire for automatic sprinkler system

 

FAQ

Q:Are you a factory or trading company?

We are a factory specialized in producing fire-fighting equipments.

 

Q: How could I visit your company?

We are located in  176  RIVER STREET UNITED LIANTANG NANAN CITY FUJIAN CHINA, about 1 hour from Guangzhou by air. We could take you up from Jinjiang or Xiamen airport.

 

 

Q: Could I get some samples?

Glad to offer the samples for free.

 

 

Q: Is OEM available?

Yes, we would try our best to meet your requirements.

 

 

Q: What's the term of payment?

T/T, L/C, West union, Paypal, Cash, etc.

 

 

 

 

 

 

 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now