Specifications
1.Hydac hydraulic oil filter element2.Filtration ratings of 74 or 125 microns
3.stainless steel wire screen media
4.ISO Test
1.Description:
HYDAC HTMS Series tank mounted Suction Strainer Elements ( Male NPT )are designed for installation into suction lines of pumps. Extra caution should be taken to ensure that the suction elements are always mounted below the minimum oil level of the reservoir.
2.Features:
Standard models have nominal filtration ratings of 74 or 125 microns.The suction strainer elements can also be supplied with a bypass valve to reduce high pressure drops caused by contaminated elements or high viscosity fluids during cold starting. The bypass valve opens at 3 psi. for best results, suction strainer elements should be sized for clean element pressure drops of no higher than 0.5 to 0.7 psi. HYDAC suction Strainer Elements are manufactured using stainless steel wire screen media.
3.Attention:
Suction strainer elements are only intended to protect hydraulic pumps against catastrophic failure caused by coarse contaminants. Suction strainer elements should be inspected and cleaned regularly. Suction strainer elements should not be used as the only filtration elements in a hydraulic system. Pressure filters and return line filters, with reasonable dirt holding capacity, must be installed to provide protection against component damage
caused by fine contaminants.
4.Hydraulic Data
Pressure Drop vs. Flow: Pressure drop will be < 2 psi when strainers are used within the recomended flow range, and with a standard hydraulic fluid with a viscosity of 141 SSU and specific gravity of 0.86.