Product Details

Electrical Dual Channel DC KWH Power Meter DC Energy Meter for EV Charging Station

Brand Name Blue Jay
Place of Origin China
Model Number DCEM-4MS
Phase Other, single phase or three phase
Output Voltage 0-1000V
Operating Temperature -25~55°C
Dimensions 72*94.5*48.5
Display Type Analog and Digital
Accuracy Class Class 1 or 0.5
Measuring Energy Range Voltage, current, etc

Product Features

DCEM-4MS Dual-channel DC energy meter is a highly integrated product for DC parameter measurement. When used with a shunt or external Hall sensor, it can accurately measure 1-2 channels DC voltages and 1-2 channels DC currents (with direction), power, total electricity, each single-circuit electricity, and other electrical parameters, and can be equipped with optional DI modules.

DCEM-4MS has RS485 and supports MODBUS-RTU communication protocol, which can upload the collected data and equipment status. DCEM-4MS is widely used in electric power, communications, railways, transportation, environmental protection, steel, and other industries to monitor the current and power consumption of DC equipment.


Function of DCEM-4MS

  • Measurement and calculation functions such as DC voltage, current, power, and forward and reverse electric energy.

  • Multi-rate electric energy metering function

  • Maximum demand measurement and demand time recording

  • Maximum value record: single-phase voltage, current, power maximum and minimum values, and occurrence time

  • Time-stamped event recording

  • power freeze

  • Supports RS485 interface MODBUS-RTU communication protocol, and one more RS485 port can be selected

  • 2-way switch input monitoring, 2-way relay output (optional)

  • Supports second DC voltage and current input (optional)

 

Feature of DCEM-4MS

  • Various anti-interference measures.

  • Convenient and flexible system wiring.

  • Easy to install, 35mm standard DIN rail installation.

  • Powerful data collection and processing capabilities.

  • Intuitive Large-size LCD screen real-time measurement information.

  • High security and good reliability
    A variety of anti-interference measures have been adopted during the design process to ensure stable operation in the power system environment. The electrostatic discharge immunity meets level 4; the electrical fast transient burst immunity meets level 4; the high voltage impact immunity meets level 4; the surge immunity meets level 3; the panel protection level meets IP54, and the shell protection level meets IP20.


PerformanceParameter
Enter Measurement DisplayDistribution networkDC
VoltageRating0-1000V
Overload Measurement: 1.2 times Instantaneous: 10 times/1s
Impedance>1 kΩ/V

RatingDC Shunt:0-75mV
currentHall current sensor:5A、20A、50A、100A、200A、300A、400A、500A optional

OverloadMeasurement: 1.2 times Instantaneous: 2 times/10s

Impedance<100mΩ
Accuracy levelClass 1 or 0.5
Clock (optional):The daily error is less than 0.5 seconds
DisplaySegment LCD display
Power supplyrangeAC/DC85V~265V
power consumption≤4VA
OutputDigital interfaceRS-485, MODBUS-RTU protocol (optional 2-Channels RS-458)
Pulse outputOptional 1 channel active electric energy pulse output,1 channel second pulse output
DI input (optional)2 DI, dry contact mode
Ri<500Ω turns on, Ri>100kΩ turns off
DI output (optional)2 DO relay
relay contact capacity: 5A/250V AC; 5A/30V DC
EnvironmentWorking environment-25~55°C Altitude ≤2000m,98%RH, no condensation, no corrosive gas
Storage environment-30~75°C
SafetyWithstand voltageInput and power supply>4kV; input and output>4kV.power supply and output>4Kv.
InsulationPower supply to shell > 5MΩ

Dimension of EV charging Station DC energy meter

You May Like

Find Similar Products By Category

View More
Chat Now Contact Now