Product Details

AMC100-ZD DC Electrical Precision Power Distribution Monitoring Device Two Channels DC Inlet For Data Base DC Multi Power Meter

Brand Name Acrel
Place of Origin China
Model Number AMC100-ZD
Phase Three Phase
Output Voltage 48VDC,240VDC,336VDC
Operating Temperature -10℃~45℃
Dimensions 180*45*90mm
Display Type Digital Only
Accuracy Class 0.5

Product Features

Products Description
AMC100-ZD

Acrel AMC100 series DC precision power distribution monitoring device is a measuring device designed specifically for power management of data center servers. The device is compact in design and can monitor the full electrical parameters, input and output switches and the status of the lightning arrester of A+B two incoming lines and 192 outgoing lines in real time. The alarm thresholds of all measurement channels can be set individually, and the outgoing line The limited event immediately triggers the system's sound and light alarms, and the high integration of the monitoring loop is realized in the volume of the traditional instrument.

Function & Parameter
Product Model
Model
Function Description
AMC100-ZA
Measurement of A+B independent 2 channels AC three-phase inlet all electricalparameters, 8DI4DO,2 channels leakage current monitoring, 1 channel Temperatureand humidity monitoring, 2-63rd harmonic, 3 channels RS485 Modbus-RTU(1 forbranch module, 1 for HMI, 1 for Supervision System)
AMC100-FA30
Measurement of A+B independent 30 channels AC outlet all electrical parameters,1channel RS485 Modbus-RTU
AMC100-FA48
Measurement of A+B independent 48 channels AC outlet all electrical parameters, 1channel RS485 Modbus-RTU
AMC100-ZD
Measurement of A+B independent 2 channels DC inlet,U,I,P,Q, 8DI/4DO, 1 channelTemperature and humidity monitoring,3 channels RS485 Modbus-RTU((1 for branchmodule, 1 for HMI, 1 for Supervision System)
AMC100-FD30
Measurement of A+B independent 30 channels DC outlet all electrical parameters, 1channel RS485 Modbus-RTU
AMC100-FD48
Measurement of A+B independent 48 channels DC outiet all electrical parameters, 1channel RS485 Modbus-RTU
AMC100-FAK30
Measurement of A+B independent 30 channels AC outlet all electrical parameters andswitch value status, 1 channel RS485 Modbus-RTU
AMC100-FAK48
Measurement of A+B independent 48 channels AC outlet all electrical parameters andswitch value status, 1 channel RS485 Modbus-RTU
AMC100-FDK30
Measurement of A+B independent 30 channels DC outlet all electrical parameters andswitch value status, 1 channel RS485 Modbus-RTU
AMC100-FDK48
Measurement of A+B independent 48 channels DC outlet all electrical parameters andswitch value status, 1 channel RS485 Modbus-RTU

Parameter

Instrument model
AMC100-ZD
Measurement parameters
Voltage,Current, Power, Electric energy, Ambient temperature and Humidity
Bus voltage
Rated
48VDC,240VDC,336VDC
Measuring range
 ±20%
Overload
Instantaneous voltage 2 times/sec
Current incoming circuit
Rated
5V(Hall sensor, ±12V powered by AMC100-ZD)

Overload
Duration is 1.2 times, instantaneous 10 times/sec
Temperature and humidity
Temperature Range
-40℃~+99℃
Humidity Range
20%~90%
Input frequency
 AC45~65Hz
Measurement accuracy
Coil in
Voltage/current level 0.5, power/electric energy level 1
Temperature
±1℃
Humidity
±5%
Auxiliary Supply
AMC100-ZD:Signal power(≤15W)  
AMC100-ZD-P24:24V independent power supply 
AMC100-ZD-P220: 
1、When the constant voltage is
DC240V、DC336V, powered by AC220V、 DC240V、DC336V independent supply 
2、When the constant voltage is DC48V,powered by DC48V independent
supply
Environment
Temperature
Work: -10℃~45℃
 Storage: -25℃~70℃ 
Humidity
Relative humidity≤95%
Altitude
≤2000m
Switch output
4-way 3A 250VAC/3A 30VDC
Switch input
8 dry nodes
Communication
1 channel isolatedRS485/Modbus-RTU to the background system
1RS485/Modbus-RTU to touch screen
1RS485/Modbus-RTU connection to the downstream module
1-channel Ethernet communication function is optional
Installation Method
DIN35mm rail or bottom plate installation
Protection level
 IP20
Pollution level
2
Security
Insulation
The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ
Withstand voltage
Voltage and current signal of line A // Voltage and current signal of line B // Switching output //Isolated communication port // Two
of other ports should meet AC2kV for 1min,switching input and other ports should meet AC0.5kV for 1min, leakage current should be less than 2mA, no breakdown or flashover phenomenon
Electromagnetic compatibility
Anti-static interference
Level 4
Reactance fast transient pulse
Level 3
Surge resistance
Level 4
Radio frequency electromagnetic radiation
Level 3
Wiring&Installation
Wiring

Installation

Dimension and Packaging
Company Profile
   Acrel Co., Ltd. [Stock Code : 300286. SZ] is a high-tech enterprise concentrating on research, production, sales and services. It mainly provides systemic solutions of energy efficiency management and electrical safety for users. ‘Acrel’ is equipped with the complete production lines from cloud platform software to sensors. Until now, it has more than 8000 sets systemic solutions used in China to help users to realize energy visual management ,supply energy data services and improve electrical efficiency and safety. ‘Acrel’ has maintained steady growth since its listing in 2012. The company will adhere to the concept of ‘innovation,high-efficiency,unity and honesty’ and it provides more high-quality solutions,products and service for power system users and micro-grid.

Contact


You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now