Product Details

rs485 Top Quality 3 Phase 4wire^^ Prepaid Energy Meter Customized Electric Power Meter kema approved

Place of Origin Zhejiang, China
Brand Name Mseed
Model Number DTSY862-1
Display Type Analog and Digital
Phase Three Phase
Measuring Energy Range 1.5(6)A, 5(20)A,10(40)A,15(60)A, 20(80)A
Accuracy Class Class1/class2
Output Voltage 3*220/380V;3*57.7/100V
Operating Temperature -25℃~+55℃
Dimensions 217*145*71 (mm)

Product Features

Product Details
Product Introduction

Quick details:

Place of Origin: Zhejiang, China (Mainland)
Brand Name: Mseed 
Model Number:DTSY862-1
Phase: Three  Phase prepaid energy meter
Input Voltage: 220/380V
Dimensions: 217*145*71(mm)
Operating Temperature: -25℃~+55℃
Output Frequency: 50 or 60Hz 

energy meter with rs485

Features

Main features: Application of computer management, power utilization after purchasing       power; limitation of maximal service power within the rated current range (prescribed by       power supply department); one card only for one watt-hour meter, no electricity interruption even with the loss of the card and ensuring the power continuation after the re-registration; bilateral transmission of data ; automatic power- cut to warn users to purchase power ;         automatic switch-off operation when the electric quantity hits zero ; certain software design of anti-electricity-theft and so on.Its ambient temperature ranges from -25℃~+55℃ and its relative humidity is no more than 85%.

wireless energy meter

Starting Current
Under the conditions of reference voltage ,reference frequency and COSφ=1.0, watt-hour     meters with load current being 0.004Ib(class 1) or 0.005Ib(class 2 ) can make continuous   metering.   smart energy meter
three phase digital energy meter
Creeping (Watt-hour meter running without current)
When the voltage circuit of the watt-hour meter does not have current, and the voltage          circuit has 115% rated power, the output pulse will not be more than one.
din rail energy meter
Voltage range
Normal working voltage: 0.9Un-1.1Un
Maximal working voltage 0.8Un-1.15Un
portable energy meter testing equipment
Power dissipation
Power dissipation of voltage circuit: ≤2W and 10VA
Power dissipation of current circuit:: ≤4.0VA
single phase energy mete

Parameters
Type
Class index
Reference voltage 
Un 
Basic current
Ib
Interface Mode
Meter 
Constant
imp/kWh
Connection Mode
DTSY862-1



DSSY862-1


Class 1

Class 2
3×220/380V

3×57.7/100V

3×100V

3×380V
1.5(6)
Mutual Inductance 
1600
Diagram 2
5(20)
Direct Mode
800
Diagram 1
10(40)
Direct Mode
400
Diagram 1
15(60)
Direct Mode
400
Diagram 1
20(80)
Direct Mode
400
Diagram 1
Current Value

Power Factor (COSφ)
Intrinsic Error (%)
direct access to meter
meter by mutual inductor
Class 1
Class 2
0.05Ib≤I<0.1Ib
0.02Ib≤I<0.05Ib
1.0
±1.5
±2.5
0.1Ib≤I≤Imax
0.05Ib≤I≤Imax
1.0
±1.0
±2.0
0.1Ib≤I<0.2Ib
0.05Ib≤I<0.1Ib
0.5(inductive) 0.8(capacitive)
±1.5
±2.5
0.2Ib≤I≤Imax
0.1Ib≤I≤Imax
0.5(inductive) 0
±1.0
±2.0
Applications

1. The watt-hour meter can be installed for use after being certificated and sealed with lead print. If there’s no seal with lead print or too long storage time , the watt-hour meter can’t be used until the department concerned does the rechecking and sealing.
bi-directional energy meter
2. The watt-hour meter should be installed in a dry and ventilated place. The soleplate for      installing the meter should be fixed in the wall that is stable, fireproof and hard to vibrate      and the watt-hour meter should be about 1.8m from the ground.
dc energy meter
3. Do the connection according to the wiring diagram, screw down the wiring bolt and fasten the plug board in terminal box.
energy meter to rs232
4. The number of actual electrical energy must come from the displayed number via mutual  inductor cut-in meter multiplying the voltage ratio.
energy meter electrical
5. “One watt-hour meter, one card”: All users’ cards can’t exchange with each other.    Another card should be purchased at the power supply department (power-sale office) after the loss.

6. Preparations for purchasing power: Users should insert IC card into the holder one time so as to send the watt-hour meter data back to computer database.
3 phase 4 wire energy meter connection
7. Power-purchasing ways: During the process of power-sale, insert IC card into the reader- writer of IC cards while reading into IC card the enciphered information by computer: the      user number, power quantity pre-purchased , way of restricting capacity and maximum         power and so on.
wireless energy meter
8. Using power card: Insert power card into the holder. If the card is valid, the watt-hour       meter will automatically show the data. The display of LCD will be in the order of : the power quantity purchased, the total power quantity purchased, the number of times the meter- card has been used , alarming quantity of electricity , limit of quantity of electricity on credit and   frequency of restricting capacity . Ensure the safekeeping of the card after drawing it out.
energy meter test bench
9. Display when the watt-hour meter is electrified: full display, serial number, constant,           version number version number ,total amount of electricity consumption, remnant power.
Working display: During the working process of watt-hour meter, remnant power, total           amount of electricity consumption will be shown alternately in 5 seconds.
remote control energy meter
10. Switch-off when over maximum power: If the watt-hour meter is set to be switched off    due to over maximum power. The watt-hour meter will be switched off for 3 minutes (before the power is restored) if the users has used power for 60 seconds under the condition of      over maximum power. If the users insert the card into the watt-hour meter, the power can     be restored at once.
single phase energy meter
11. Hoarding limit: If power quantity purchased+ remnant power ﹥hoarding limit, power       quantity purchased won’t be read in .The power in the card will still be valid and users need to go to the power-sale department to have the power quantity rewritten.
din rail energy meter
12. Alert reminder: When the remnant power in the card is less than “the quantity of             electricity to the limit of light alarms ”, “alarm light” will flash to remind users to               purchase power.
portable energy meter testing equipment
13. Power failure warning: When remnant power is less than “the quantity of electricity to the limit of power- cut ” , power is cut to alarm users and “Power-cut ” prompt is shown.   At this moment users insert IC card into the holder, the power will be recovered immediately and “alarming light” will be on all the time as a warning. If the power is allowed to be over-drafted after remnant power is used up, uses need to operate a switch after the overdrawn   power is used up; otherwise, the switch-off will be operated automatically.
energy meter wireless plug
14. Malfunction report: When remnant power is displayed zero or a negative number,          “ Power-cut ” prompt will be shown. If watt-hour meter is sill working, users should            purchase power at once and report this condition to power supply department. 

Dimension
Packing Details

Being packed according to the international standard is to guarantee safe delivery during the transportation. 

Why Choose Us

•Professional manufacturer with internationally standard production lines and a devoted technical team.

•Strict test procedure with advanced test equipment

•Responsive and responsible service team.

•Door to door service when needed.

•Helpful and enthusiastic in developing the buyers’ business. 

 

•Treat your career as our career. 

Certifications:

Welcome to contact us:

For sales or information inquiry, please contact us in the following ways:
Mob:+8613588948309
Tel: +86-577-55770369
Skype: +8613588948309

WhatsApp:+8613588948309
Trade messenger:barbara ye
Website: http://mseed.en.china.cn
               

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now