Product Details

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

Type Other, Examination Therapy Equipments, Auto-measuring and auto-diagnosing
Model Number ECG-3303G
Place of Origin Guangdong, China

Product Features

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor ECG

 

 

Portable ECG manager with the development of electronic, communicative and software technique, It has significant meaning for the early-stage prediction for cardiovascular disease and family medical health care, It has great promotion on size, power consumption, and data storage and data transmision, property and quality, It is great influence on the life security of the patients.

 

 

 

ECG manager use analog low-pass and analog high-pass analog filter just like components band-pass to filter out signal interference, while the use of active notch filter frequency of 50Hz can further filt out interference, getting a more pure ECG signal. And then through the implementation of A/D conversion, single-chip processing system, the final test results will be displayed by LCD. The ECG analyzer has good characteristics such as low-power, portable and real-time and so on.

 

Feature:

1. For the cardiovascular disease testing

2. Use for family medical health care

3. Portable and automatic analysis

4. Precise dataflow analysis and persistent record

 

Features: 3303B,3303G (3 channel)
1. Compact in size, easy and direct operation, portable
2. Accurate pace pulse identification and automatic analysis function
3. Four working modes: Manual / Auto / Physical Examination / Storage
4. Alphabet keyboard fast inputting clinical information (only for ECG-3303G)
5. Built-in USB, RS232 interface, ECGNET software optional
6. 12 leads simultaneous waveforms display
7. 80mm, 3 channel format recording
8. Advanced [Freeze] function
9. 5" 800x480 graphic 5 inch color LCD
10. Adapt to 110-230V,50/60Hz AC power supply
11. Built-in rechargeable Li-ion battery
10. 250 patient information storage (Exendable)
11. USB interface allows net transmission
12. USB flash disk and USB printer connected
13. Memory for 100 ECG
14. Safety standards: Class I, type CF.
15. QWERTY Full Alpha Numeric key Board / Soft touch key Board.
Specification:
Lead: Standard 12 leads
Lead acquisition: 12bit/1000Hz(synchronously 12 leads)
Work mode: Manual / Auto / Physical Examination / Storage
Filter:
AC Filter:50Hz/60Hz
EMG Filter: 25Hz/45Hz
Auti-Drift Filter: 0.15Hz (Adaptive)
CMMR:100dB(with AC Filter)
Input circuit: Floating; Protection circuit against Defibrillator effect
Input Impedance:50MΩ
Input circuit current:0.05μA
Patient current leakage: <10μA
Calibrating voltage: 1mV±2%
Voltage tolerance: ±500mV
Time constant: 3.2s
Frequency response: 0.05~160Hz(-3dp)
Noise level: <15u Vp-p
Inter-channel Interference: 0.5mm
Sensitivity: Auto, 2.5,5,10,20,40mm/mV
Recording mode:
3ch, 3ch+
Default Man. Mode is 3ch format
Default Auto. Mode is 3ch+ format
Paper speed: 6.25, 12.5,25,50mm/s(±3%)
Paper: 80mm Roll Paper
Communication: RS232/USB port
Power supply: AC 110-230V(±10%),50/60Hz(±1Hz), 60VA
DC Built-in rechargeable battery, 14.4V(2000mAh)
Dimension/Weight: 330x270x75mm/2.8kg

 

 

Product Details: Structure & Function

 

1. Front Panel and LCD

 Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

  (1) Handle (2) Paper Switch (3) Paper Cover (4) LCD (5) Keypad

 

2. Control Keypad Panel

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine 

The function of Keypad

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

  Symbols on the device body:

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

 

3. BottomPanel and Lateral Panel

  Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

Patient Cable Interface

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine 

 
Analog I/O and UART Interface (RJ11) :Used for
* Record analog External Input In [TEST] lead of [MAN] mode.
* Export the Rhythm Lead of the [BASIC] menu to Analog External Output.
* Communicate with personal computer for 12 lead real-time ECG transmission and ECG
files transmission.(Needs optional ECG Archive Software and UART/USB cable).

 

 Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

 

USB/Host Interface (Optional) :Used for

Transmit ECG file to ECG Archive software based on personal computer, Please refer to the ECG Software Operation Manual for more information.
* Save ECG files to a external USB disk via USB/Host interface; the files can be imported into ECG Archive software, Please refer to the User Manual for more information.
* Print ECG report to a external USB printer(PCL command) via USB/Host interface; details about the supported USB printer, please contact our service department.
CAUTION:The USB cable should be well shielded and can not be longer over 3 meters, It's better to use the manufacturer's recommended USB cable.

 

USB or LAN Interface (USB/RJ45,Optional) :Used for
* Communicate with personal computer system(This need a optional ECG Archive software, Please refer to the ECG Software Operation Manual for more information).
CAUTION:The USB or LAN cable should be well shielded and can not be longer over 3 meters, It's better to use the manufacturer's recommended USB cable.

 

 

4. Connecting Electrodes(as following)

The identifier and color code of electrodes used comply with IEC requirements. In order to avoid
incorrect connections, the electrode identifier and color code are specified in below Table. The
equivalent code of American standard is given too.

 

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

The Limb/Chest electrode should be placed on body surface shown as following:

 

V1 : Fourth inter-costal space at right border of sternum.
V2 : Fourth inter-costal space at left border of sternum.
V3 : Fifth rib between V2 and V4.
V4 : Fifth inter-costal space at left mid-clavicular line.
V5 : Left anterior axillary line at the horizontal lever of V4.
V6 : Left anterior mid-axillary line at the horizontal lever of V4.

 

 

 

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

NOTE : Tangling of electrodes or overlap from one place to another of ECG creamis not allowed.

 

 

5. ECG Explanation on measurement

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

 

6. ECGNET (sell in addition)

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

ECG software display on the computer

 Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

 

 

Package: 1pc / inner box , 4pcs / carton

Digital Portable Handheld Electronic Monitor ECG, Digital Portable Handheld Electronic Monitor Arrythmia Analysis ECG Machine

 

 

Factory:

1. Quality first spirit

2. Professional service team

3. Convenient transport

4. Certificate: Medical CE

 

 

Company profile:

Chongqing Joywell Trade Co.,Ltd.  has been in Chongqing China in 1999, It has a professional team to engage at international business and a long-term cooperated factories as powerful backing.

 

Qulity spirit, wonderful service and team work are always the first. Through develop more than 10 years, we have lifted up a new stage and established a wide customer group which from United States, United Kingdom, Cannada, Germany, Japan, South Korea, Iran, New Zealand, Qatar, Irealand, Spain, Netherland, Chile, etc.

 

The team cooperation open up and share innovation.

AIM: Employee's success is the success of the company.

VALUE: Intergrity first, customer first, cooperation sharing, happy passion, refince on active, thanksgiving growth.

MISSION: Let customer satisfaction, let the Joywell products are well-known in the world.

VISION: To meet the challenge, success!

 

We would like cooperate with clients from all over the world.

 

 

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now