Fetal Monitor can acquire fetal heart rate, maternal uterine contraction when pregnancies over 28 weeks to provide reference data for clinical use.The monitor can be used individually or connected with PC through RJ45 Interface for the purpose of central monitoring. It is only suitable for the equipment in hospitals, clinics, doctors offices and patients at home by professional medical personnel.
Features: -
- Light dexterous appearance, tops horizontally and walls can be hoisted
- 8.0 "screen color LCD display, rotatable screen to 60°
- Display of the patient data and curve clearly
- FHR 120 BPM~160 BPM normal range label
- Sound and color alarm for high and low fetal heart rate
- Continuous 24-hour real-time monitoring function
- Continuous 12-hour patient curve and data storage , playback and print
- With picture freeze function
- Optional English interface
- Single, Twins Monitoring optional
- 9 crystal board band pulsed wave transducer
- Extra-long life, high-resolution built-in thermal recorder
- Built-in communication port, can be connected with central monitoring system.
Main Performance :
Security:
Anti-shock types:
Facilities I, no internal power supply Anti-electric Shock Degree: B Working Voltage: AC 100 V~240 V Frequency: 50 Hz/60 Hz P<60 VA Fuse: T1.6AL250VDisplay Dimensions: 8.0 "color LCD display, folding 60 degree
Display
Content: bed No. , pregnancy weeks, age, paper speed, date, time , volume, alarm status, transducer connection status, recorder status, FHR data and wave, Contraction data and wave, Fetal move times and mark etc.
Print:
- Record Paper two-double type Z
- Print Width: 112 mm
- Valid Print Width: 104 mm
- Paper output speed: 1 cm/min,2 cm/min,3 cm/min(optional)
- Data Precision: ±5 %(X Roll),±1 %(Y Roll)
Record Content: hospital , bed No. ,name, pregnancy weeks, patient No., paper speed, date, time , FHR data and wave, Contraction data and wave, Fetal move times and mark etc.
Fetal Marking
For the manual button (the operation of pregnant women), there will be a mark display in the bottom area of FHR wave display section.
FHR Alarm:
Alarm for high and low FHR, which exceeds appointed limit.
Accessories
Sell in standard:
- Transducers(Ultrasound TransducerⅠ, TOCO Transducer, Remote Marker)
- Abdomen belt
- Record Paper
- Power supply line
- Earth line
- Two Fuses
- User manual
Sell in addition
- Ultrasound Transducer Ⅱ
Ultrasound Probe | |
Nominal Frequency | 1.0 MHz |
Work Frequency | 1.0 MHz±10 % |
Negative peak sound pressure | p_<1 MPa |
Output beam intensity | Iob<20 mW/cm2 |
The peak time space peak intensity | Ispta<100 mW/cm2 |
The average time space peak intensity | Isata<10 mW/cm2 |
FHR Rang | 50 BPM~240 BPM |
Resolution | 1 BPM |
Accuracy | ±2 BPM |
TOCO | |
TOCO range | 0~100 % |
Resolution | 1 % |
Nonlinear error | <±10 % |
RZ way | Manually |
Physical Characteristics | |
Size | 320 mm (length) × 260 mm (width) × 80 mm (height) |
Weight | about 3 kg |