Specifications
1.atx power switch2.Original Meanwell
3.Prompt Delivery: 3~5 days
4.Fast delivery High quality
5.2 years warranty
Welcome to Hope Hill Family
Meanwell IPC-200 200W 3.3V 5V 12V switch atx power supply
Main Features
♦ Meet 1U rack mount system
♦ Universal AC input / Full range
♦ Active power factor 94%
♦ Protections:Short circuit / Overload / Over voltage
♦ Forced air cooling by built-in DC fan
♦ With power good and fail signal output
♦ Built-in remote ON-OFF control
♦ Remote DC sense +5V and +3.3V
♦ With +5VSB:0 ~ 2.0A max.
♦ 100% full load burn-in test
♦ High efficiency
♦ 2 years warranty
Specifications
♦ atx power switch
♦ Original Meanwell
♦ Prompt Delivery: 3~5 days
♦ Fast delivery High quality
♦ 2 years warranty
MODEL | IPC-200 | ||||||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH4 | CH5 | CH6 |
DC VOLTAGE | 3.3V | 5V | 12V | -5V | -12 | 5VSB | |
RATED CURRENT | 15A | 25A | 13A | 0.5A | 1A | 2A | |
CURRENT RANGE | 0~15A | 1~25A | 1~13A | 0~0.5A | 0.1~1A | 0~2A | |
RATED POWER NOTE.8,9 | 200W continue Combine power max:+5V,+3.3V,+12V output shall not exceed 180W max.(The+5&+3.3Volt combine total output shall not wxceed 150W)(The -5$-12Volt combine total output shall not exceed 12W) | ||||||
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 50mVp-p | 120mVp-p | 100mVp-p | 120mVp-p | 50m Vp-p | |
VOLTAGEADJ.RANGE | CH2:5.05~5.5V | ||||||
VOLTAGE TOLERANCE Note.3 | CH1:5.0% | 5.0% | 7.0% | 8% | 10% | 5.0% | |
LINE REGULATION | 1.0% | 1.0% | 1.0% | 2.0% | 2.0% | 1.0% | |
LOAD REGULATION | 5% | 5% | 7% | 8% | 10% | 5.0% | |
SETUP, RISE TIME | 800ms 20ms/230VAC 2500ms,20ms/115VAC at full load | ||||||
HOLD UP TIME(TYP) | 16ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR |
| ||||||
EFFICIENCY (Typ.) | 75% | ||||||
AC CURRENT (Typ.) | 3.5A/115VAC 1.7A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 40A/115VAC 80A/230VAC | ||||||
LEAKAGE CURRENT | 3mA/240VAC | ||||||
PROTECTION | OVER LOAD | 105~150% rated output power | |||||
Protection type :Shut down o/p voltage,re-power on to recover | |||||||
OVER VOLTAGE | +3.3V,+5V:110%~140% of rated voltage:+12V:13.2V~16V | ||||||
Protection type :Shut down o/p voltage,re-power on to recover | |||||||
SHORT CIRCUIT | All output equipped with short circuit | ||||||
Protection type :Shut down o/p voltage,re-power on to recover | |||||||
FUNCTION | POWER GOOD SIGNAL | The TTL compatible signal with 100~500ms delay after set up | |||||
POWER FALL SIGNAL | The TTL compatible signal with go down at least 1ms before +5V below 4.75V | ||||||
PS-ON INPUT SIGNAL | Power ON:PS-ON=”Low”.or”>2V”;Power OFF:PS-ON=”Hi” .or”<1.5V” | ||||||
ENVIRONMENT | WORKING TEMP. | -10~ +60 oC(Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85 , 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | 0.05%/ oC(0 ~ 50 ) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | UL60950-1,TUV EN60950-1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P:,I/P-FG,O/P-FG:50M Ohms/500VDC | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B,Design refer to FCC part 15Class B | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,EB55024,EN61000-6-2(EN50082-2) heavy industry level, criteria A | ||||||
OTHERS | MTBF | 94.1Khrs min. MIL-HDBK-217F (25 ) | |||||
CONNECTOR | ATX main power connector *1ea;+12V power cinnector *1ea | ||||||
Peripheral power cinnector *3ea ;Floppy drive power connector *1ea | |||||||
COOLING | Forced air ventilation by 4cm DC fan | ||||||
DIMENSION | 240*83*40mm (L*W*H) | ||||||
PACKING | 1.44Kg;10pcs/15.4Kg/0.89 CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. |