Product Details

CHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

Product Features

  Specifications  

Product Description:

1. Conductors: copper or aluminum.

2. Both armored and non-armored type power cables are available.

3. Voltage rating: 0.6/1kV 3.6/6kV 6/10kV 8.7/15kV 26/35kV.

4. PVC or PE sheathed.

5. Number of cable cores: one core (Single core),two cores(Double cores),three cores,

Four cores (Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),

Five cores (Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).

6. Standards: IEC 60502.IEC, BS, DIN, ASTM, CSA, NFC, AS, GOST etc. Or other special characteristics as customers request.

CHINA 0.6/1kv 1*400 PVC insulated NYY Power CableCHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

NYY-J PVC insulated Electric Power Cable

Application:

Power and control cable for fixed installation. Can be used indoors, outdoors, underground, in concrete and in water.

Standards:

IEC60502-1
Generally to VDE0276 and VDE0271.

Conductor:

re conductor: Class 1 solid plain copper to IEC60502-1
rm conductor: Class 2 stranded copper
rm conductor: Class 2 round stranded plain copper conductor, multi wire to BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228, CENELEC HD383
sm conductor: Class 2 sectorial stranded plain copper conductor to BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228, CENELEC HD383

Insulation:
PVC (Polyvinyl Chloride) Type YI4 to VDE0276
Filler:
PVC (Polyvinyl Chloride)
Sheath:
FR/PVC (Flame Retardant / Polyvinyl Chloride) to IEC60502-1
Sheath Colour:
Black
Voltage Rating:
600/1000V
Temperature Rating:
Fixed: -40 to +70°C
Flexing: -5 to +50°C
Minimum Bending Radius:
Single core: 15 x overall diameter
Multicore: 12 x overall diameter
Core Identification:
Up to and including 5 core: colour coded or number coded
7 core and above: number codeCHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

             CHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

1.Standard :

IEC60502,GB/T 12706

 

2. Voltage :

   33kv 

3. Specification:

Type

Designation

Application

VV

Copper conductor ,PVC insulated ,PVC sheathed power cable

For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct

VLV

Aluminium conductor ,PVC insulated ,PVC sheathed power cable

VY

Copper conductor, PVC insulated, PE sheathed power cable

VLY

Aluminium conductor ,PVC insulated ,PE sheathed power cable

VV22

Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force

VLV22

Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV23

Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable

VLV23

Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable

VV32

Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable

 

For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces

VLV32

Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV33

Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable

VLV33

Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable

Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied

 CHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

4. Nominal Cross-sectional Areas:

1.5 mm2 , 2.5 mm,4 mm2 , 6 mm2 , 10 mm, 16 mm2 ,25 mm, 35 mm2 , 50 mm,70 mm, 95 mm,120 mm,150 mm2 ,185 mm,240 mm2 ,300 mm2  400 mm2 500 mm2 630 mm2 800 mm2

 

5. Production Range:

single core cable from 1.5 mmto 800 mm2,muli-core cable from 1.5 mm2   to 400 mm2

 

6. Operating Characteristics:

Rated power-frequency voltage u0/u:0.6/1 KV

Max permissible continuous operating temperature of conductor 70

Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor  300 mm2

 

The ambient temperature under installations should not be below 0

 

The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter.

 

 CHINA 0.6/1kv 1*400 PVC insulated NYY Power Cable

 

 

 Any inquiries, pls feel free to contact me.~We will give you the best prices. ~~~

 

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now