Product Details

500w 3000w 1.5kw 36v 250w small bldc hub motor kit wheel BLDC HUB MOTOR for car

Product Features

Product Display

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

 

Motor typeOutput PowerVoltageLoadSpeedRated TorqueEfficiencyNoiseIP Class
KWVARPMNm%dB
VOL- IEC90S2250-2P2.25220 ac6.4230007.169262IP 54
VOL- IEC100S2250-4P2.25220 ac6.42150014.339262IP 54
VOL- IEC112S2250-6P2.25220 ac6.42100021.489262IP 54
VOL- IEC112S3750-2P3.75220 ac10.70300011.9492.562IP 54
VOL- IEC112S3750-4P3.75220 ac10.70150023.8892.562IP 54

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

Process Flow

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car 

About Us

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car 

Packing&Transport

500w 3000w 1.5kw 36v 250w small  bldc hub motor kit wheel BLDC HUB MOTOR for car

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn.
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now