Product Details

Central air conditioning system training device educational technology equipment

Place of Origin Guangdong, China
Brand Name GTEE
Model Number GTRT-0002

Product Features

 

 

 

Product Description 

Brief introduction:

Central air conditioning system training device can simulate real process of building central air conditioning system. It can demonstrate "summer refrigeration cycle" and "winter heating cycle" process of the central air conditioning. The system includes "the electrical control system" and "central air conditioning models." It can training students’ various skills of central air conditioning system design, load calculation, electrical design, piping design, energy management and cost estimates.

Structure and compositions:

1. The electrical control system

Electrical control system uses electrical control cabinet type and its size is approximately 600 × 500 × 1800mm. By the central air-conditioning special controller, leakage switch, signal lights, selector switch, thermal relay control buttons, multi-function digital temperature meter, digital voltage meter, temperature transmitters and other components in accordance with the central air-conditioning control flow design

2. Central air conditioning models

Central air conditioning models are miniature in accordance with real central air conditioning, including the "refrigeration cycle system" and "heating circulation system." All components are using industrial components to meet the national standards, the model installed on the top of the square steel frame, with its bottom mounted with universal wheel.

2.1 Refrigeration cycle system: It mainly includes compressor, evaporator, condenser, solenoid valves, filters, expansion valve, sight glass, accumulator, spray cooling towers, cooling water pumps, cooling water pumps.

2.2 Heating circulation system: It mainly includes analog electric boilers, hot water circulating pump, etc.

2.3 Simulated room: The main frame is made of industrial profiles. wall and plate are all using environmentally friendly packaging.

Technical parameter:

System parameter:

1.1)           Input power: AC380V±10%,50Hz

1.2)           Cooling capacity:7.5KW

1.3)           Maximum Input Power: 6.5KW

1.4)           Rated heating power: 2.0KW

1.5)           Rated current: 7A

1.6)           Flow rate: 700m3/h

1.7)           Refrigerant: R22

1.8)           Leakage current: 30mA

1.9)           Dimension: approximately 6000mm*2400mm*2500mm

1.10)      Security measures: four kinds of protective measures in line with national standards: overvoltage, over current, overload, leakage and grounding.

1.11)      Working temperature: Ambient temperature: -5 °C ~ 40 °C.

Parameter requirement of the electrical control system

(1) Central air conditioning dedicated controller: well-known brand, bus control technology.

(2) Relay elements: contactors, relays, push button switches, temperature transmitters, leakage switch, indicator light, and temperature controller.

(3) Instrumentation: Multi-function digital temperature controller, temperature display meter, ammeter, uses voltmeter, etc., to monitor operating current and voltage of the compressor, fan, circulating water pump actuator, and monitor component’s temperatures of outlet, return air, the condenser.

(4) Process monitoring and temperature acquisition:

It uses computer to carry out the central air conditioning process monitoring, control and data acquisition (outlet temperature, return air temperature, chilled water outlet temperature of the cooling water and so on). Control mode must include manual mode, auto mode and computer remote control mode. It uses multi-file switch to make the exchange of the three control modes.

Manual mode: That is using different buttons on the control cabinet door to start and stop the corresponding devices. Such as: Press the “chilled water pump start button SB1", chilled water pumps in operation status, chilled water indicator lights. Press the “chilled water pump stop button SB2", chilled water pumps stopped running, chilled water indicator goes off. Manual mode is generally used when it is in debugging or commissioning phase. Auto mode: Press the ‘system start button’ on the control cabinet door. And then the system gradually opens the main fans, cooling water pumps, refrigeration and other equipment according to PLC default logical order until the system is fully put into operation. During operation, the system gradually stops the device in a logical order by pressing the "stop button system". Computer remote control mode: That is using the computer to control the central air conditioning system. Manual mode and auto mode can be also used in the computer user interface. At the same time, the computer can carry out the functions like data acquisition, monitoring, report generation and fault alarming recording.

Configurations:

No

Name

QTY

Remark

1

Central air conditioning units

1

Central air conditioning specified units, evaporator, condenser, tank, fan coil units, piping (sight glass, pressure gauge, etc.). Cooling / chilled water pumps, more than 0.18Kw.

2

Cooling towers

1

 

Specs:more than 2T

3

Simulated rooms

1

Industrial profile bracket, environmentally friendly materials Wall.

4

Electrical control cabinet

1

Specs:about 600*500*1800mm,standard electrical cabinet. Composition:controller, operation terminals, contactor, relays, data collector, buttons, indicators, fault setting boards, digital instrument, etc.

5

Operation Manuals

1

A booklet, e-manual is available and factory manuals of master components are available too.

 
Our Services

Specializing in the development and manufacturing of professional automotive teaching equipment, air conditioning and refrigeration teaching equipment, electrical and electronic teaching equipment and lift teaching and other training equipment.

 
Company Information

About us

A preferred and trusted, one-stop source for educational equipment. A leading scientific partner for schools, universities, science laboratories and research institutions. We are located in Baiyun District, Guangzhou and adjacent to Guangzhou Baiyun International Airport.

Our Mission

It is to offer a reliable, high-quality product and to provide outstanding service.

Our Main Market

Mid East, Eastern Europe, Africa, Western Europe, domestic Market.  

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now