Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL-BL6K0A72 | 6 | 72 | 88.65 | 1500 | 38.2 | 94 | 62 | IP 54 |
VOL-BL6K0A110 | 6 | 110 ac | 33.50 | 1500 | 38.2 | 94 | 62 | IP 54 |
VOL-BL6K0A220 | 6 | 220 ac | 16.75 | 1500 | 38.2 | 94 | 62 | IP 54 |
VOL-BL6K0A380 | 6 | 380 ac | 9.70 | 1500 | 38.2 | 94 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.
You May Like
- 4500W 6500W 110V 1500RPM brushless dc motor
- 5KW 6500W 7000W 110V 1500RPM brushless dc motor
- low voltage 1500rpm 24v 300w brushless dc motor with high efficiency
- high efficiency 1500rpm 400w 24v brushless dc motor
- high efficiency 1500rpm brushless dc motor 72v 400w
- Class F 400w 110v brushless dc motor 1500rpm
- hall sensors 500w 24v 1500rpm brushless dc dmotor
- high torque 1500rpm 500w brushless dc motor 48v with IP54
- CE certificate 110v 500w 1500rpm brushless dc motor
- 100% copper wire 500w 220V 1500rpm brushless dc motor
Popular Searches
Find Similar Products By Category
You May Like
- 48v 3000w 1200 watt 3kw 24v stator lamination sine wave control brushless dc motor with control
- 48v 600w 1500rpm power brushless dc motor with hall sensors
- sensored 600w 72v 1500rpm electric brushless dc motor
- Custom permanent magnet 24v 48v 220Vac 1500rpm 24v 600w brushless dc motor with IP54
- 550W 12V Battery powered Brushless DC Motor
- long life 1500rpm 24v 700w BLDC brushless dc motor
- long life 1500rpm 220v 700w brushless dc motor
- Low voltage 3000rpm 12v 300w brushless dc motor for fan
- 1hp 3000rpm 24 v ruitenwisser single phase synchronous permanent magnet brushless dc motor
- weight of 48v 1000w 48v 660w 12v 12volt 48v 48v 2.2kw 2800rpm 2000 rpm 24-50vdc ic brushless dc motor
- 1kw 100 nm electric encoder mount marathon bicycle automatic gate parts brushless DC motor
- 1500RPM 60V 4000W short delivery time BLDC Brushless DC Motor
- HFM015 custom use small aircraft electric cars brushless dc 1500rpm 48v 48 volt 5kw 5000w bldc motor
- 4.5KW 1800rpm 220v variable speed brushless dc motor
- 2HP 72V brushless motor 1000RPM for Lawn mower