Product Details

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

Type Clinical Examination Aids
Brand Name Contec
Model Number CMS9000
Place of Origin Hebei, China

Product Features

Specifications

1. Low-priced medical device manufacturers
2. Lightweight,compact and portable
3. Built-in rechargeable lithium battery

Product Name:         

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital   

                    

Introduction:

 

This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module, display and recorder in one device to form a high cost-performance, high safety and low power consumption device.

 

Detailed picture:

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Major Features:

 

1. Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.

 

2. Be applicable for adult, pediatric and neonatal.

 

3. Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.

 

4. Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance.

 

5. 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously.

 

6. Monitoring contents, scan speed, volume and output contents can be set optionally.

 

7. Storage of 480-hour trend data, and review of 40-second holographic waveform.

 

8. Storage and review of 72-hour ECG waveform.

 

9. Function of NIBP review, storage for up to 2400 NIBP data.

 

10. Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

 

11. Calculation of drug concentration.

 

12. Network: connecting with central station, other Bed observation and software updating.

 

13. Connection mode: wireless and wired.

 

14. Built-in rechargeable battery for uninterrupted monitoring, built-in printer(optional).

 

15. Print ECG, SpO2, RESP, BP and temperature data with one-key.

 

16. Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

 

17. Analysis function for heart rate variability(HRV) (optional).

 

18. Power supply: 220V, 50Hz

 

Main performance: 

 

ECG:

 

1. Lead Mode: 3-lead and 5-lead are optional

 

2. Lead Selection I, II, III, avR, avL, avF, V

 

3. Wave 5-lead: 2 channels

 

4. 3-lead: 1channel

 

5. Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV

 

6. Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV

 

7. HR Measuring and alarm Range: 15 ~ 300 bpm

 

8. Accuracy: ±1% or ±1bpm, which is greater

 

9. Alarm Accuracy: ±2bpm

 

10. Resolution: 1 bpm

 

11. CMRR

     (1). Monitor ≥ 100 dB

     (2). Surgery ≥ 100 dB

     (3). Diagnosis ≥ 60 dB

 

12. Bandwidth

     (1). Surgery 1 ~ 20 Hz(+0.4dB,-3dB)

     (2). Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB)

     (3). Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB)

     (4). Calibration Signal 1 mV (Vp-p), ±5%  Accuracy

 

13. ST Segment Monitoring

     Measuring and Alarm Range -0.6 mV~ + 0.8 mV

 

    14. ARR

    (1). ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

    (2). Alarm Available

    (3). Review Available

    (4). Scan Speed for ECG Waveform is adjustable:

          12.5mm/s accuracy ±10%

          25mm/s accuracy±10%

          50mm/s accuracy±10%

 

RESP:

 

1. Method: R-F(RA-LL) Impedance

 

2. Differential Input Impedance: >2.5 MΩ

 

3. Measuring Impedance Range: 0.3~5.0Ω

 

4. Baseline Impedance Range: 100Ω– 2500Ω

 

5. Bandwidth: 0.3 ~ 2.5 Hz

 

6. Resp. Rate

   (1). Measuring and Alarm Range: 0~120rpm

   (2). Resolution: 1 rpm

   (3). Measuring Accuracy: ±2 rpm

   (4). Alarm Accuracy: ±3rpm

   (5). Apnea Alarm: 10 ~ 40 S

 

SpO2:

 

1. Measuring Range: 0 ~ 100 %

 

2. Alarm Range: 0 ~ 100 %

 

3. Resolution: 1 %

 

4. Accuracy: 70% ~ 100% ±2% ; 0% ~ 69% unspecified

 

5. Pulse Rate(PR)

   (1). Measuring and Alarm Range 0~250bpm

   (2). Resolution 1bpm

   (3). Measuring Accuracy ±2bpm or ±2%, which is greater

   (4). Alarm Accuracy ±2bpm

 

NIBP:

 

1. Method: Oscillometry

 

2. Mode: Manual, Auto, continuous

 

3. Measuring Interval in AUTO Mode: 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min

 

4. Measuring Period in Continuous Mode: 5 Min

 

5. Measuring and Alarm Range: 10~270mmHg

 

6. Alarm Type: SYS, DIA, MEAN

 

7. Resolution:

 

   (1). Pressure  1mmHg

 

   (2). Cuff Pressure ±3 mmHg

 

   (3). Accuracy ±10% or ±8mmHg, which is greater

 

8. Over-pressure Protection:

 

   (1). Adult Mode 315±10 mmHg

 

   (2). Pediatric Mode 265±10 mmHg

 

   (3). Neonatal Mode 155±10 mmHg

 

TEMP:

 

1. Channel: dual-channel

 

2. Measuring and Alarm Range: 0 ~ 50°C

 

3. Resolution: 0.1°C

 

4. Accuracy: ±0.1°C

 

5. Actualization Interval: about 1 Sec.

 

6. Average Time Constant: < 10 Sec.

 

7. Alarm responding Time: ≤2min

 

EtCO2(optional):

 

1. Method: Sidestream or Mainstream

 

2. Measuring Range for CO2: 0~150mmHg

 

3. Resolution for CO2:

   (1). 0.1 mm Hg 0 to 69 mm Hg
   (2). 0.25 mm Hg 70 to 150 mm Hg

 

4. Accuracy for CO2:

   (1). 0 – 40 mm Hg ±2 mm Hg
   (2). 41 – 70 mm Hg ±5%
   (3). 71 – 100 mm Hg ±8%
   (4). 101 – 150 mm Hg ±10%

 

5. Respiration Rate: >80BPM ±12%

 

6. AwRR Range: 2~150 rpm

 

7. AwRR Accuracy: ±1BPM

 

8. Apnea Alarm: Available

 

IBP(optional):

 

1. Channel: dual-channel

 

2. Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

 

3. Measuring and Alarm Range: -50~350 mm Hg

 

4. Resolution: 1 mm Hg

 

5. Accuracy: ±2% or 1mm Hg, which is greater

 

Physical Characteristic:

 

1. Dimension: 310×140×263(mm)

 

2. Net weight: 3.8Kg

 

Certification:

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

-------------------------------------------------------------------------------

 

Fine quality is our promise

 

Considerate service is our responsibility

 

Passing on health is our wish

 

Your satisfaction is our pursuit

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

Chinese Low-priced Reliable Outstanding Good-quality Medical Device Manufacturers For Hospital

 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now