Outdoor column circuit breaker rod type high voltage circuit breaker

Product Features

Photos of Details and workshop

The picture is the workshop photo of the company, the company is determined to high standard and efficient,
customer-driven,technological innovation, quality and quantity.
Outdoor post circuit breaker
Used for transmission projects with long power supply radius, large voltage drop and low voltage The phase switch can not only be used as the section switch on the 12kV distribution trunk line, branch line and ring line of urban network, but also be used as
the input line switch in rural network, industrial and mining enterprises, living quarters and construction sites.
Product size drawing
1. The circuit breaker adopts three-phase pillar structure, vacuum arc extinguishing technology, and has the characteristics of stable and reliable closing and breaking performance, no risk of combustion and explosion, maintenance free, small size, light weight and long life, etc.

2, the circuit breaker adopts fully enclosed structure, the vacuum arcing chamber in the conductive circuit and the inner wall of the outer insulation sleeve adopts the silicone rubber sealing casting method, the sealing performance is good, improve the moisture-proof, anti-condensation performance, especially suitable for cold or wet areas.

3. The three-phase pillar and current transformer adopt imported outdoor epoxy resin solid insulation, or indoor epoxy resin solid silicone rubber insulation;With high and low temperature resistance, UV resistance, aging resistance and other characteristics.
Serial number
Project
Unit
Numerical value
1
Nominal voltage
kV
12
2
Rated frequency
Hz
50
3
Rated current
A
630
1250
4
Rated short circuit breaking current (RMS)
kA
20
25
5
Rated peak tolerable current (peak)
kA
50
63
6
Rated short-time tolerable current (4s) (effective value)
kA
20
25
7
Rated short circuit closing current (peak)
kA
50
63
8
Mechanical life
time
10000
9
Rated short circuit breaking current breaking times
time
30
10
Power frequency withstand voltage (1min) :(effective value)
Interphase, opposite ground/fracture
kV
42
11
Lightning shock withstand voltage (peak)
kV
75
12
 Power frequency voltage resistance of the secondary circuit for 1min
V
2000
Serial number
Project
Unit
Numerical value
1
Nominal voltage
kV
12
2
Rated frequency
Hz
50
3
Rated current
A
630
1250
4
Rated short circuit breaking current (RMS)
kA
20
25
5
Rated peak tolerable current (peak)
kA
50
63
6
Rated short-time tolerable current (4s) (effective value)
kA
20
25
7
 Rated short circuit closing current (peak)
kA
50
63
8
mechanical life
time
10000
9
Rated short circuit breaking current breaking times
time
30