Product Details

CZT100C Marine air exhaust axial flow fan

Electric Current Type AC
Mounting Duct Fan
Blade Material Other, Aluminum
Place of Origin Shandong, China
Brand Name YAOSEN
Model Number CZT series
Voltage 220/230/380/400/415/420/440/480V etc.
Certification CCC, CSA, GS, ROHS, Other, CCC, CSA, GS, ROHS, CCS/ABS/RINA/RS/BV/DNV/LR/GL/VR etc
After-sales Service Provided Overseas service center available

Product Features

    CZT100C Marine air exhaust axial flow fan      

   CZT series Marine Ventilation Fan For Ship Use

 

 

1.Technical data:

Diameter:1000mm
Air flow:33000~48000M3/H
Pressure:470~320PA
Power:7.5KW
Frequency: 50/60HZ
Brand:Yaosen Marine

 

2.General

CZT series Marine ventilation fan for ship (simply the fans) are capable of blowing air, such as ocean air containing salt vapor and corrosive air containing a small quantity of oil vapor. They are suitable for cabin air ventilation and exchange on oceangoing vessels. They are also applicable in other places that suit.

The fan is designed and manufactured according to the standard of GB11864 marine or Navy Axial Flow Fans and The manufacture Rules of Sea-going Steel Ships.

  

3.Characteristics

CZT series Marine ventilation fan for ship Casing can be opened. 

Reverse rotation possible. 

Good anti-corrosiveness. 

Strong performance in anti-swing, vibration-proof and impact resistant

 

4.Structure type

CZT series Marine ventilation fan for ship is manufactured with a built-in casing motor structure. The vane wheel is directly mounted on the motor shaft.

The vane wheel is made of anti-corrosive case aluminum alloy while the casing is made of welded common steel.

As desired, the casing can either be made into an integral one or an open type along the axial direction. In the later case, the vane wheel and the casing so as to bring convenience for on-the-spot repair and the replacement of its spare parts.

Viewed from the motor side, the vane wheel rotates clockwise while in service the ventilator is allowed to rotate reversely.

The ventilator can be matched with marine DC motor of 380V, 50HZ or 440V,60HZ.

 

5.Working Conditions

Medium temperature: -25°C ~ +50°C

Max relative humidity: 95%

Periodical swing:±22.5°

Continued transversal incline:±15°

Continued longitudinal incline:±10°

Vibration: existent

Impact: existent

 

6.CZT Marine Axial Fan Drawings

Please contact us and get detailed Technical parameters and Drawings.

We could Design and Produce the Marine fan,Industrial Fan,and Other Ventilation Equipment according to your detailed requirement !

 

7.Introduction for ordering

7.1 Please introduce the model, flow prate, pressure, speed and structure of fan,50HZ or 60HZ.

7.2  If the fan on the deck, according to relevant provisions of the chassis thickness.

7.3 Please offer insulation class and protection class for fan motor (if not, the insulation class is F, protection class is IP56).

7.4 Our factory can offer the fans of special specification and usage according to the user's demands.

7.5 We are responsible for the repair, exchange and return of the products Within 18 months. 

 

8.Use and maintenance

8.1 Before installing the fans, should check whether each part is intact, whether the components are complete, whether the impeller and casing rotating direct are concordant.

8.2 When installing the duct of the inlet and outlet, should make the duct and fans be spontaneous identical, not join them forcing, not bring the weight of duct on the fans.

8.3After installed the fans, check whether there is friction of collide between the impeller and the fixed parts by rotating the impeller. If collision, friction, loud noise or strong vibration happened, the fan should be restart after checking. Avoid the fan being bumped and other substance or liquid entered the fans. Please clean the dust on blade of impeller in time, so as not to break the balance and strengthen the noise.

8.4 The  fans should be started-up while the inlet is opening,

8.5After the fans wiring, the terminal box should be sealed, avoid the air or water in it.

8.6As the fans operating, the motor electric current should be control strictly, not exceed the rated electric current. Avoid the motor burning,

8.7The fans maintain must be done on stop working time. When burning, after check, should whether the every part of fans is normal.

8.8As some fault occurred in fans operating, should find out the reason in time and think a way of resolution.

 

9.Main products:

CBL series marine explosion-proof centrifugal fan

CBZ series marine explosion-proof axial flow fans

CGDL Series marine or navy high efficiency low noise centrifugal fans

CLZ series Marine high pressure axial-flow fans

CQ series Marine High pressure centrifugal ventilator

CSL series centrifugal water power fans for marine use

CSZ series water driven gas free axial flow fans for marine or navy use

CWL(CXL) series marine small-size Centrifugal fans

CWZ series marine or navy small-sized axial fans

CZF series marine axial-flow fans

JCL(CLQ)series marine centrifugal ventilator fan

CZ Series marine axial-flow ventilator fan

CDZ series Marine low noise axial fans for marine or navy use

CBGD series marine explosion-proof (non-sparking) centrifugal fan

CZT Series Marine axial flow fan for ship use 

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now