50HZ / 60Hz 220V / 380V High Frequency Online UPS Commercial Ups Systems

Brand Name IWELL
Place of Origin China
Model Number CE10KS , CE15KS , CE20KS

Product Features

Delivery Time:7-10 working days
Certification:CE/FCC/ISO9001

10-20Kva Three Phase Input Single Phase Output High Frequency Online UPS 380V / 220Vac

DSP Technology

Active input power factor correction (PFC)

Wide range of input voltage and frequency

Zero power switch delay

Active Load Management

Sufficient Expansion Slots

The load power factor is 0.8

Support the Generators: The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generators and provide safe and reliable power supply.

Model# 3CE10K 3CE15K 3CE20K Comments
Input
Input voltage
Rated voltage 380VAC/220VAC  
Phase three phase with ground  
Turn on voltage range (120±5~274±5)VAC  
Bypass voltage range (60±5~300±5)VAC Could be adjusted by software.
Bypass low loss 60VAC~220VAC(default 60VAC)  
Bypass low comeback Low loss +5VAC  
Bypass high loss 220VAC~300VAC(default 300VAC)  
Bypass high comeback High loss -5VAC  
Line low loss/comeback (120±5) VAC /(140±5) VAC load≤50%
(150±5) VAC /(165±5) VAC 50%<load≤80%
(160±5) VAC /(180±5) VAC load>80%
Line high loss/comeback (274±5)VAC/(260±5)VAC  
Input frequency
Rated frequency 50Hz  
Frequency low loss (40~49) ±0.2Hz(default:46Hz) Could be adjusted by software.
Frequency low comeback Frequency low loss +0.5Hz  
Frequency high loss (51~60)±0.2Hz(default:54Hz)  
Frequency high comeback Frequency high loss -0.5Hz  
Input power factor
Input power factor > 0.95 220VAC,full R load
Generator  Support generator input Generator rating≥2*UPS rating
Input current
Rated current  45A 68A 91A  
Input THDI <= 25%  
Output protection
Rating protection 50A Breaker 80A Breaker 100A Breaker  
Output power
VA/watt 10KVA/8KW 15KVA/12KW 20KVA/16KW  
Rated voltage 220VAC Sine wave
Voltage range 200/208/220/230/240VAC Could be adjusted by software. 10% derating for 208VAC/200VAC.
Voltage regulation ±1%  
Voltage distortion ≤6% Full RCD load
≤2% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output before turn-on YES  
Crest ration 3:01  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or
Input frequency<46Hz)
 
Battery mode (50+0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 90%  
Battery mode > 88%  
Overload