ARTON based in Chernivtsi, Ukraine began over 13 years ago. Our founder and CEO has an engineering background and strong working knowledge of plastic moulding, electrical and optical devices construction. He saw the perspective in the security industry by the rapid growth. ARTON under his leadership has grown from its small beginnings to become the leading brand in its field. ARTON designs, manufactures and markets fire alarm and security devices (conventional photoelectric smoke, heat, combined detectors, manual call points, fire alarm control panels, intruder detectors, accessories etc.).
Product Types:
1. Fire Detectors
2. Fire Alarm Control Panels
3. Accessories, etc.
2-Zone Conventional Fire Alarm Control Panel:
ARTON-02F
fire alarm control panel
EN54-2:2003
EN54-4:2003
Designed for centralized and stand-alone protection of various applications against fires and unauthorized intrusion by controlling statuses of up to 2 alarm loops.
FEATURES:
- each of panel’s loop can be adjusted as: fire alarm loop with verification, without verification or waiting for second detectors’ activation.
- The panel defines and displays the following statuses of a fire alarm loop: “Standby”, “Attention” (verification of alarm loop or activation of the first detector), “Fire”, “Fault – SC”, “Fault – OC”, “AL disabled”.
- Passive and active detectors can be interconnected to one AL, combined alarm loops can be constructed using 2- and 4- wire wiring diagrams.
- The possibility of changing the threshold deviation current in AL to determine detectors’ activation (separately for passive and active detectors).
- The possibility of construction of combined ALs with verification or expectation for 2 detectors activation and priority of manual call point‘s activation.
- Sounder-beacon output with ≤500 mA load current.
- 2 programmable powerful outputs “P1” and “P2” (≤200 mA current load) with programmable operation logics and operation options as 4-wire AL power output, detector output or incommutable power output of auxiliary devices (+12V).
- The panel defines the following types of faults and statuses: short-circuit or open-circuit of AL, short-circuit of outputs, load break of outputs “Light/Sound”, “Fire”, “Fault”, no voltages powering outputs and AL, no 220 V power, fault of storage battery etc.
- 2 programmable user access codes and 1 engineer access code.
- Possibility to assign rights for each user to control the certain AL.
- Slot for auxiliary modules’ connecting. Auxiliary modules: BR4-4 blocking relays, BSKT-1 auto-dialing module through commutable telephone lines, BSKM-1 GSM-communicator, BSPC-1 computer coupler.
- Review of current configuration and programming (configurating) of the panel made from inbuilt keypad or from a computer using BSPC-1.
TECHNICAL SPECIFICATIONS:
Mains supply voltage | 187-242 V AC 50±1 Hz |
Battery size | 12±15%V 7Ahr |
Max AC power | 30 W |
Max storage battery current consumption | 1,0 A |
Standby AC power | < 15 W |
Standby operation time of the panel powered by the fully charged storage battery at mains outage | ≤24 hours, including ≥3 hours in the “Fire” mode |
Max number of circuits | 2 |
N.O. contact supply voltage | 15 (±1) V |
Output voltage at rated load | 12 (±2) V |
Total line resistance (not considering EOL resistor) | ≤220 Ohm |
Resistance of leakage between lines (EOL resistor disabled) and between each AL line and panel’s enclosure | ≥50 kOhm |
AL current interpreted by the panel as Open-circuit | from 0 to 3 mA |
AL current interpreted by the panel as Short-circuit | >20 mA |
Short-circuit limit current in AL | ≥24 mA |
the AL status change duration the panel responses to the AL status change duration the panel doesn’t issue the message about | ≥80 ms
≥50 ms |
Max number of active detectors (SPD-3, SPD-3.5, SPD-3.10, SPT-2B, SPT-3B etc.) interconnected to one loop. Max total current should not exceed 3 mA. | 32 |
Auto-reset time (disablement time) of AL at verification (set by a user) | ≥5 s |
Time of expectation for repeated triggering after AL resetting, the panel goes to the “Fire” mode on detecting it | 60±1 s |
Specifications of connectable bells, sounders and beacons | 12 (±2) V, 500 mA |
Max current load of 4-wire detector outputs | 200 mA |
Max current load of “Fire”, “Alarm”, “Fault” | 40 mA |
Meantime-between-failures | 30000 hours |
Average lifetime | 10 years min |
Dimensions | 200x300x80 mm |
Weight (battery excluding) | 2,5 kg |
Specification:
Place of Origin | Ukraine |
Brand Name | ARTON |
Model Number | ARTON-02F |
Usage | Fire |
Number of zones | 2 |
Type | Conventional |
Average lifetime | 10 years min |
Dimensions | 200x300x80 mm |
Weight | 2,5 kg |
Minimum Order Quantity | 300 Piece/Pieces |
Port | Odessa |
Packaging Details | Packed in Carton. |
Delivery Time | 2-4 weeks |
Payment Terms | L/C,T/T,PayPal |
Supply Ability | 100000 Piece/Pieces per Month |